Transbronchial lung biopsy: A review of 85 cases.
Open Access
- 1 October 1977
- Vol. 32 (5) , 546-549
- https://doi.org/10.1136/thx.32.5.546
Abstract
Transbronchial lung biopsy using the fibreoptic bronchoscope was carried out in 85 patients. There were no serious complications; two patients had a 10% pneumothorax and 17 had slight haemoptysis lasting less than 24 hours. The problems of interpreting small biopsy specimens are considered. Satisfactory specimens were obtained without fluoroscopic guidance, particularly in diffuse and lobar lesions. A histological diagnosis was made in 62% of diffuse lesions and compatible histology was found in a further 22%. In a further case Pneumocytis carinii infection was diagnosed. Blind biopsy of discrete periheral lesions was less successful with only one positive diagnosis in 12 patients.Keywords
This publication has 8 references indexed in Scilit:
- TRANSBRONCHIAL BIOPSY VIA FLEXIBLE FIBEROPTIC BRONCHOSCOPE - RESULTS IN 164 PATIENTSPublished by Elsevier ,1976
- Transbronchial Lung Biopsy via the Fiberoptic BronchoscopeChest, 1975
- Transbronchial Forceps Lung Biopsy Through the Fiberoptic Bronchoscope in Pneumocystis Carinii PneumoniaChest, 1974
- A Safe Procedure for Diagnosis of Pneumocystis carinii PneumoniaChest, 1974
- Transbronchial lung biopsy via the fiberoptic bronchoscope.Published by Elsevier ,1974
- Complications of fiberoptic bronchoscopy.Published by Elsevier ,1974
- Transbronchoscopic Lung Biopsy for Diffuse Pulmonary Diseases: Technique and Results in 450 CasesChest, 1972
- TRANSBRONCHOSCOPIC LUNG BIOPSY IN DIFFUSE PULMONARY DISEASE.1965