Importance of matrix: Analyte ratio for buffer tolerance using 2,5-dihydroxybenzoic acid as a matrix in matrix-assisted laser desorption/ionization-fourier transform mass spectrometry and matrix-assisted laser desorption/ionization-time of flight
- 1 August 1998
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 9 (8) , 805-813
- https://doi.org/10.1016/s1044-0305(98)00046-4
Abstract
Many biological samples destined for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) contain buffers. The presence of these buffers often inhibits the ability to obtain spectra. Here, the results of a study of the effects of six different buffers on spectra of three representative small proteins are reported utilizing 2,5-dihydroxybenzoic acid as matrix. These proteins, bovine insulin, cytochrome c, and bovine albumin have masses from ∼5000 to 66,000 Da. Three different sample preparation techniques were investigated: aerospray, dried-drop, and acetone redeposition. Both MALDI Fourier transform and time-of-flight mass spectrometry results show that buffer tolerance of MALDI-MS samples depends upon several factors, including the relative amount of the buffer in the MALDI matrix, as well as the identity of the specific buffer. Furthermore, the rate at which buffer tolerance decreases as buffer concentration is increased varies from buffer to buffer. The current results reveal that, at very high matrix:analyte ratios, buffer tolerance of MALDI is dramatically greater than concluded in previous literature reports.Keywords
This publication has 37 references indexed in Scilit:
- Analysis of Peptide and Protein Samples Containing Surfactants by MALDI-MSAnalytical Chemistry, 1997
- Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and ProteinsAnalytical Chemistry, 1996
- Probe-Immobilized Affinity Chromatography/Mass SpectrometryAnalytical Chemistry, 1995
- Analysis of High-Mass Biomolecules Using Electrostatic Fields and Matrix-Assisted Laser Desorption/Ionization in a Fourier Transform Mass SpectrometerAnalytical Chemistry, 1995
- Growing protein‐doped sinapic acid crystals for laser desorption: An alternative preparation method for difficult samplesJournal of Mass Spectrometry, 1993
- Are proton transfer reactions of excited states involved in UV laser desorption ionization?Journal of Mass Spectrometry, 1992
- Design and optimization of a micropump-based electrospray device for preparation of nitrocellulose substrates for plasma desorption time-of-flight mass spectrometryJournal of Mass Spectrometry, 1992
- Matrix‐assisted laser desorption/ionization of high‐mass molecules by Fourier‐transform mass spectrometryRapid Communications in Mass Spectrometry, 1992
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Electro-spraying: A method of making samples for β counting allowing accurate correction for self-scattering and self-absorptionNuclear Instruments and Methods, 1961