Automated Detection and Quantitation of Bacterial RNA by Using Electrical Microarrays
- 7 June 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (14) , 4794-4802
- https://doi.org/10.1021/ac0600914
Abstract
Low-density electrical 16S rRNA specific oligonucleotide microarrays and an automated analysis system have been developed for the identification and quantitation of pathogens. The pathogens are Escherichia coli, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus, and Staphylococcus epidermidis, which are typically involved in urinary tract infections. Interdigitated gold array electrodes (IDA-electrodes), which have structures in the nanometer range, have been used for very sensitive analysis. Thiol-modified oligonucleotides are immobilized on the gold IDA as capture probes. They mediate the specific recognition of the target 16S rRNA by hybridization. Additionally three unlabeled oligonucleotides are hybridized in close proximity to the capturing site. They are supporting molecules, because they improve the RNA hybridization at the capturing site. A biotin labeled detector oligonucleotide is also allowed to hybridize to the captured RNA sequence. The biotin labels enable the binding of avidin alkaline phophatase conjugates. The phosphatase liberates the electrochemical mediator p-aminophenol from its electrically inactive phosphate derivative. The electrical signals were generated by amperometric redox cycling and detected by a unique multipotentiostat. The read out signals of the microarray are position specific current and change over time in proportion to the analyte concentration. If two additional biotins are introduced into the affinity binding complex via the supporting oligonucleotides, the sensitivity of the assays increase more than 60%. The limit of detection of Escherichia coli total RNA has been determined to be 0.5 ng/μL. The control of fluidics for variable assay formats as well as the multichannel electrical read out and data handling have all been fully automated. The fast and easy procedure does not require any amplification of the targeted nucleic acids by PCR.Keywords
This publication has 28 references indexed in Scilit:
- Impact of microarray technology in nutrition and food researchMolecular Nutrition & Food Research, 2005
- Direct Profiling of Environmental Microbial Populations by Thermal Dissociation Analysis of Native rRNAs Hybridized to Oligonucleotide MicroarraysApplied and Environmental Microbiology, 2003
- Portable System for Microbial Sample Preparation and Oligonucleotide Microarray AnalysisApplied and Environmental Microbiology, 2001
- Accurate sequencing by hybridization for DNA diagnostics and individual genomicsNature Biotechnology, 1998
- Expression monitoring by hybridization to high-density oligonucleotide arraysNature Biotechnology, 1996
- Detection of heterozygous mutations in BRCA1 using high density oligonucleotide arrays and two–colour fluorescence analysisNature Genetics, 1996
- Microelectrode arrays and application to biosensing devicesBiosensors and Bioelectronics, 1994
- Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassayAnalytical Chemistry, 1993
- Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiencyAnalytical Chemistry, 1990
- Reversible coordination and facilitated transport of molecular nitrogen in poly((vinylcyclopentadienyl)manganese) membraneJournal of the American Chemical Society, 1989