Ultratrace Determination of Lead in Whole Blood Using Electrothermal Atomization Laser-Excited Atomic Fluorescence Spectrometry
- 1 January 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (18) , 3199-3203
- https://doi.org/10.1021/ac9603587
Abstract
Laser-excited atomic fluorescence has been used to detect lead that was electrothermally atomized from whole blood in a graphite furnace. A 9 kHz repetition rate copper vapor laser pumped dye laser was used to excite the lead at 283.3 nm, and the resulting atomic fluorescence was detected at 405.8 nm. No matrix modification was used other than a 1:21 dilution of the whole blood with high-purity water. Using the atomic fluorescence peak area as the analytical measure and a background correction technique based upon a simultaneous measurement of the transmitted laser intensity, excellent agreement for NIST and& CDC certified whole blood reference samples was obtained with aqueous standards. A limit of detection in blood of 10 fg/mL (100 ag absolute) was achieved.Keywords
This publication has 15 references indexed in Scilit:
- Coulometric stripping potentiometryElectroanalysis, 1995
- Determination of lead in whole blood using inductively coupled argon plasma mass spectrometry with isotope dilutionJournal of Analytical Atomic Spectrometry, 1995
- Electrothermal isotope dilution inductively coupled plasma mass spectrometry method for the determination of sub-ng ml–1levels of lead in human plasmaJournal of Analytical Atomic Spectrometry, 1994
- A rapid Zeeman graphite furnace atomic absorption spectrometric method for the determination of lead in bloodSpectrochimica Acta Part B: Atomic Spectroscopy, 1993
- Development of a laser-excited atomic fluorescence spectrometer and a method for the direct determination of lead in Great Lakes watersAnalytica Chimica Acta, 1992
- Current needs for increased accuracy and precision in measurements of low levels of lead in bloodEnvironmental Research, 1992
- Monitoring human exposure to lead: An assessment of current laboratory performance for the determination of blood leadEnvironmental Research, 1992
- Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a l'vov platform and matrix modifierThe Analyst, 1987
- Laser-excited atomic fluorescence spectrometry in an atomic absorption graphite tube furnaceJournal of Analytical Atomic Spectrometry, 1987
- Sub-picogram detection of lead by non-flame atomic fluorescence spectrometry with dye laser excitationSpectrochimica Acta Part B: Atomic Spectroscopy, 1974