Comparison of a Multiplexed Fluorescent Covalent Microsphere Immunoassay and an Enzyme-Linked Immunosorbent Assay for Measurement of Human Immunoglobulin G Antibodies to Anthrax Toxins
Open Access
- 1 January 2004
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 11 (1) , 50-55
- https://doi.org/10.1128/cdli.11.1.50-55.2004
Abstract
Recently, the Centers for Disease Control and Prevention reported an accurate, sensitive, specific, reproducible, and quantitative enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) antibodies to Bacillus anthracis protective antigen (PA) in human serum (C. P. Quinn, V. A. Semenova, C. M. Elie et al., Emerg. Infect. Dis. 8:1103-1110, 2002). The ELISA had a minimum detectable concentration (MDC) of 0.06 μg/ml, which, when dilution adjusted, yielded a whole-serum MDC of 3.0 μg of anti-PA IgG per ml. The reliable detection limit (RDL) was 0.09 μg/ml, while the dynamic range was 0.06 to 1.7 μg/ml. The diagnostic sensitivity of the assay was 97.6% and the diagnostic specificity was 94.2% for clinically verified cases of anthrax. A competitive inhibition anti-PA IgG ELISA was also developed to enhance the diagnostic specificity to 100%. We report a newly developed fluorescence covalent microbead immunosorbent assay (FCMIA) for B. anthracis PA which was Luminex xMap technology. The FCMIA MDC was 0.006 μg of anti-PA IgG per ml, the RDL was 0.016 μg/ml, and the whole-serum equivalent MDC was 1.5 μg/ml. The dynamic range was 0.006 to 6.8 μg/ml. Using this system, we analyzed 20 serum samples for anti-PA IgG and compared our results to those measured by ELISA in a double-masked analysis. The two methods had a high positive correlation ( r 2 = 0.852; P < 0.001). The FCMIA appears to have benefits over the ELISA for the measurement of anti-PA IgG, including greater sensitivity and speed, enhanced dynamic range and reagent stability, the use of smaller sample volumes, and the ability to be multiplexed (measurement of more than one analyte simultaneously), as evidenced by the multiplexed measurement in the present report of anti-PA and anti-lethal factor IgG in serum from a confirmed clinical anthrax infection.This publication has 15 references indexed in Scilit:
- Method for Simultaneous Measurement of Antibodies to 23 Pneumococcal Capsular PolysaccharidesClinical and Vaccine Immunology, 2003
- Simultaneous Detection of 15 Human Cytokines in a Single Sample of Stimulated Peripheral Blood Mononuclear CellsClinical and Vaccine Immunology, 2003
- Specific, Sensitive, and Quantitative Enzyme-Linked Immunosorbent Assay for Human Immunoglobulin G Antibodies to Anthrax Toxin Protective AntigenEmerging Infectious Diseases, 2002
- A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular PolysaccharidesAmerican Journal of Clinical Pathology, 2002
- Optimized Production and Purification of Bacillus anthracis Lethal FactorProtein Expression and Purification, 2000
- Validation of serological assays for diagnosis of infectious diseasesRevue Scientifique et Technique de l'OIE, 1998
- Calibration and assay development using the four-parameter logistic modelChemometrics and Intelligent Laboratory Systems, 1993
- [13] Purification and characterization of adenylyl cyclase from Bacillus anthracisPublished by Elsevier ,1991
- Estimation of Average Concentration in the Presence of Nondetectable ValuesApplied Occupational and Environmental Hygiene, 1990
- The use of non-linear regression analysis and the F test for model discrimination with dose-response curves and ligand binding dataJournal of Theoretical Biology, 1987