Search for Neutron Emission from a Deuterium-Titanium System

Abstract
Search for neutron emission from a titanium-deuterium system has been performed in a wide temperature range (from 77 K to 1100 K), with a D/Ti atomic percentage up to 165%. The sample was continuously monitored for 40 days, both at constant temperature and in nonequilibrium conditions. No neutron emission above background was observed.

This publication has 5 references indexed in Scilit: