The effect of implantation on the physical properties of silicone rubber
- 1 November 1974
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 8 (6) , 357-367
- https://doi.org/10.1002/jbm.820080603
Abstract
Medical grade silicone rubber manufactured by Dow Corning Corporation was implanted subcutaneously in beagle dogs. At specified time intervals, the implants were removed at which time physical properties and weight changes were determined. A change in the physical properties was observed after six months implantation. Tensile strength decreased 7%, elongation 10% and the modulus at 200% extension increased 8%. After two years implantation, tensile strength had decreased 8%, elongation 15%, and 200% modulus increased 16%. After two weeks implantation, a 0.4% weight gain was seen, and after four weeks implantation the samples had gained 0.7%. However, after four weeks the weight gains stabilized and from four weeks to two years, they never exceeded 0.91%. The increase was due mainly to lipid absorption. No phospholipid or protein was detected. A chloroform/methanol extraction of the samples before implantation demonstrated 1.7% extractable silicone polymer. Samples not extracted before implantation, but extracted after implantation also demonstrated 1.7% extractable silicone polymer. This data suggests extractable silicone polymer does not leach from the medical grade silicone rubber during implantation.The data also suggests that the rubber is not being degraded to extractable silicone polymers during implantation. There were no significant differences in percent lipid up‐take or the lipid profiles between samples which had extractable silicone polymer extracted before implantation and/or those which were not extracted before implantation.It should be pointed out that the slight changes in physical properties measured in this study should not be great enough to alter the performance of the rubber in the subcutaneous environment.Keywords
This publication has 11 references indexed in Scilit:
- In vivo testing of silicone rubber joint implants for lipid absorptionJournal of Biomedical Materials Research, 1972
- Bio‐Compatibility in selection of materials for implantationJournal of Biomedical Materials Research, 1970
- Critical obstruction of prosthetic heart valves due to lipid absorption by SilasticThe Journal of Thoracic and Cardiovascular Surgery, 1970
- L’infiltration lipidique des protheses valvulaires de starrJournal of Atherosclerosis Research, 1968
- Fatal degeneration of the silicone rubber ball of the Starr-Edwards prosthetic aortic valveThe American Journal of Cardiology, 1968
- MATERIALS AND HEART VALVE PROSTHESESAnnals of the New York Academy of Sciences, 1968
- Death Due to Swelling of Ball Component of Aortic Ball-Valve ProsthesisNew England Journal of Medicine, 1967
- Elastomers for Use in Heart ValvesRubber Chemistry and Technology, 1966
- ForewordCirculation, 1966