Stent and Artery Geometry Determine Intimal Thickening Independent of Arterial Injury
- 22 February 2000
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 101 (7) , 812-818
- https://doi.org/10.1161/01.cir.101.7.812
Abstract
Background —Clinical trials show that larger immediate postdeployment stent diameters provide greater ultimate luminal size, whereas animal data show that arterial injury and stent design determine late neointimal thickening. At deployment, a stent stretches a vessel, imposing a cross-sectional polygonal luminal shape that depends on the stent design, with each strut serving as a vertex. We asked whether this design-dependent postdeployment luminal geometry affects late neointimal thickening independently of the extent of strut-induced injury. Methods and Results —Stainless steel stents of 3 different configurations were implanted in rabbit iliac arteries for 3 or 28 days. Stents designed with 12 struts per cross section had 50% to 60% less mural thrombus and 2-fold less neointimal area than identical stents with only 8 struts per cross section. Sequential histological sectioning of individual stents showed that immediate postdeployment luminal geometry and subsequent neointimal area varied along the course of each stent subunit. Mathematical modeling of the shape imposed by the stent on the artery predicted late neointimal area, based on the re-creation of a circular vessel lumen within the confines of the initial stent-imposed polygonal luminal shape. Conclusions —Immediate postdeployment luminal geometry, dictated by stent design, determines neointimal thickness independently of arterial injury and may be useful for predicting patterns of intimal growth for novel stent designs.Keywords
This publication has 14 references indexed in Scilit:
- The restenosis paradigm revisited: An alternative proposal for cellular mechanismsPublished by Elsevier ,2010
- A mAb to the β2-leukocyte integrin Mac-1 (CD11b/CD18) reduces intimal thickening after angioplasty or stent implantation in rabbitsProceedings of the National Academy of Sciences, 1998
- Coronary angioplasty and intracoronary thrombolysis are of limited efficacy in resolving early intracoronary stent thrombosisJournal of the American College of Cardiology, 1996
- A Randomized Comparison of Antiplatelet and Anticoagulant Therapy after the Placement of Coronary-Artery StentsNew England Journal of Medicine, 1996
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomyJournal of the American College of Cardiology, 1993
- Novel approach to the analysis of restenosis after the use of three new coronary devicesJournal of the American College of Cardiology, 1992
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJournal of the American College of Cardiology, 1992
- Behaviour of vascular smooth muscle cells during repeated stretching of the substratum in vitroAtherosclerosis, 1983