Prognostic Validity of Brainstem Electric Response Audiometry in Infants of a Neonatal Intensive Care Unit
- 1 January 1991
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 30 (5) , 249-265
- https://doi.org/10.3109/00206099109072889
Abstract
This study compared the results of brainstem electric response audiometry (BERA) in infants of a neonatal intensive care unit to those obtained on the same children with pure-tone audiometry at 3 years of age. Six hundred children were initially tested in infancy, and complete follow-up information was obtained on 333. In 297 (89%) the BERA results accurately predicted the hearing status at the age of 3 years. Twenty-nine (9%) of the discrepancies were related to conductive hearing losses: 17 patients with a conductive hearing loss in the first few months of life had normal hearing at 3 years, and 12 patients normal in infancy had a conductive loss at 3 years. Two patients evaluated as a sensorineural hearing loss by BERA had normal hearing. These may have been due to a conductive loss. Six patients assessed as normal by BERA had significant hearing losses at the age of 3 years. Five of these had normal hearing at one frequency between 1000 and 4000 Hz. The sixth may have developed a sensorineural hearing loss after birth.Keywords
This publication has 22 references indexed in Scilit:
- Brainstem Electric-Response Audiometry in Infants of a Neonatal Intensive Care UnitInternational Journal of Audiology, 1987
- The Effect of 2000-4000 Hz Hearing Sensitivity on ABR ResultsEar & Hearing, 1986
- Prognostic validity of auditory brainstem evoked response screening in newborn infantsAmerican Journal of Otolaryngology, 1985
- Hearing loss in early infancy: Incidence, detection and assessmentThe Laryngoscope, 1985
- The Crib-O-Gram in the NICUEar & Hearing, 1985
- The Auditory Brain Stem Response Reliably Predicts Hearing Loss in Graduates of a Tertiary Intensive Care NurseryEar & Hearing, 1984
- A Comparison of Auditory Brain Stem Response and Behavioral Screening in High Risk and Normal Newborn InfantsEar & Hearing, 1984
- Evaluating the Efficiency of Auditory Brainstem Response as a Neonatal Hearing Screening TestSeminars in Hearing, 1984
- Accuracy of Auditory Brainstem Evoked Response with Hearing Level UnknownAnnals of Otology, Rhinology & Laryngology, 1982
- Preferred Method For Clinical Determination Of Pure-Tone ThresholdsJournal of Speech and Hearing Disorders, 1959