Post‐plasma‐spraying heat treatment of the HA coating/Ti‐6Al‐4V implant system
- 1 February 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (2) , 191-198
- https://doi.org/10.1002/jbm.820270208
Abstract
The metal/ceramic interface that constitutes an important part of the plasma-sprayed HA-coated Ti-6Al-4V system may, in fact, represent the “weak link” in the implant design. A post-plasma-spray heat treatment to enhance chemical bonding at the metal/ceramic interface and, hence, improve the mechanical properties (interface fracture toughness and tensile coating adhesion strength) of the plasma-sprayed implant system does show promise. In preliminary heat treatment studies, however, any improvements realized were lost due to the chemical instability of the coating in a moistureladen environment, with a concomitant loss in bonding properties. This deterioration in properties appears to be related to environmentally assisted crack growth as influenced by processing conditions. Still, an ability to improve HA/Ti-6Al-4V bonding through enhanced diffusion bonding was demonstrated, warranting further heat treatment studies involving atmosphere control during processing. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 12 references indexed in Scilit:
- Student research award in the undergraduate, Master candidate category, or health science degree candidate category, 17th annual meeting of the society for biomaterials, scottsdale, AZ may 1–5,1991. Characterization of the interface in the plasma‐sprayed HA coating/Ti‐6Al‐4V implant systemJournal of Biomedical Materials Research, 1991
- The Effect of Partial Coating with Hydroxyapatite on Bone Remodeling in Relation to Porous-coated Titanium-alloy Dental Implants in the DogJournal of Dental Research, 1991
- A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfacesJournal of Biomedical Materials Research, 1990
- Mechanical and Chemical Characterization of a Metal-Bioceramic InterfaceMRS Proceedings, 1989
- Calcium phosphate‐coated porous titanium implants for enhanced skeletal fixationJournal of Biomedical Materials Research, 1988
- Plasma sprayed coatings of hydroxylapatiteJournal of Biomedical Materials Research, 1987
- Evaluation of hydroxylapatite-coated titanium dental implants in dogsJournal of Oral and Maxillofacial Surgery, 1987
- Structural analysis of hydroxyapatite coatings on titaniumBiomaterials, 1986
- The fatigue strength of porous‐coated Ti–6% Al–4% V implant alloyJournal of Biomedical Materials Research, 1984
- Compliance calibration of a family of short rod and short bar fracture toughness specimensEngineering Fracture Mechanics, 1983