Amperometric choline biosensor fabricated through electrostatic assembly of bienzyme/polyelectrolyte hybrid layers on carbon nanotubes
- 21 February 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 131 (4) , 477-483
- https://doi.org/10.1039/b516038c
Abstract
We report a flow injection amperometric choline biosensor based on the electrostatic assembly of the choline oxidase (ChO) enzyme and a bienzyme of ChO and horseradish peroxidase (HRP) onto multi-wall carbon nanotubes (MWCNT) modified glassy carbon (GC) electrodes. These choline biosensors were fabricated by immobilization of enzymes on the negatively charged MWCNT surface through alternately assembling a cationic poly(diallydimethylammonium chloride) (PDDA) layer and an enzyme layer. Using this layer-by-layer assembling approach, a bioactive nanocomposite film of PDDA/ChO/PDDA/HRP/PDDA/CNT (ChO/HRP/CNT) and PDDA/ChO/PDDA/CNT (ChO/CNT) was fabricated on the GC surface. Owing to the electrocatalytic effect of carbon nanotubes, the measurement of faradic responses resulting from enzymatic reactions has been realized at low potential with acceptable sensitivity. The ChO/HRP/CNT biosensor is more sensitive than the ChO/CNT one. Experimental parameters affecting the sensitivity of biosensors, e.g., applied potential, flow rate, etc., were optimized and potential interference was examined. The response time for this choline biosensor is fast (few seconds). The linear range of detection for the choline biosensor is from 5.0 × 10−5 to 5.0 × 10−3 M and the detection limit is about 1.0 × 10−5 M.Keywords
This publication has 39 references indexed in Scilit:
- Carbon Nanotubes‐Based Amperometric Cholesterol Biosensor Fabricated Through Layer‐by‐Layer TechniqueElectroanalysis, 2004
- Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrodeAnalytical Biochemistry, 2004
- Direct Electrochemistry of Catalase at a Gold Electrode Modified with Single‐Wall Carbon NanotubesElectroanalysis, 2004
- Long‐Range Electrical Contacting of Redox Enzymes by SWCNT ConnectorsAngewandte Chemie International Edition in English, 2004
- Disposable Carbon Nanotube Modified Screen‐Printed Biosensor for Amperometric Detection of Organophosphorus Pesticides and Nerve AgentsElectroanalysis, 2004
- In VivoLactate Editing with Simultaneous Detection of Choline, Creatine, NAA, and Lipid Singlets at 1.5 T Using PRESS Excitation with Applications to the Study of Brain and Head and Neck TumorsJournal of Magnetic Resonance, 1998
- Proton Detection of Choline and Lactate in EMT6 Tumors by Spin-Echo-Enhanced Selective Multiple-Quantum-Coherence TransferJournal of Magnetic Resonance, Series B, 1996
- Design of a choline sensor via direct coating of the transducer by photopolymerization of the sensing layerSensors and Actuators B: Chemical, 1995
- Ruthenized screen-printed choline oxidase-based biosensors for measurement of anticholinesterase activityMicrochimica Acta, 1995
- Neuronal loss in different parts of the nucleus basalis is related to neuritic plaque formation in cortical target areas in alzheimer's diseaseNeuroscience, 1985