Glaucoma Detection by Stratus OCT
- 1 May 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 16 (3) , 302-306
- https://doi.org/10.1097/ijg.0b013e318032e4d4
Abstract
Purpose: To investigate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) summary report parameters from Stratus optical coherence tomography (OCT) in glaucoma patients. Patients and Methods: We obtained Stratus OCT measurements of peripapillary circle scans (average values) of the regular image resolution "FAST RNFLT" protocol, and of 1 circle scan of the high resolution "RNFLT" protocol in one eye of each of 62 glaucoma patients with mild or moderate visual field (VF) loss and 90 healthy subjects. Sensitivity, specificity, and diagnostic accuracy [(true positive + true negative)/all] were evaluated for all summary report parameters including the newer (eg, "Imax," the maximum thickness point in the inferior quadrant) at the normative limits of the Stratus OCT. Results: The diagnostic accuracy of full circle RNFLT using the 5% normal limit was 89% with the FAST RNFLT and 87% with the RNFLT protocol; this was at least as good as any other parameter. The diagnostic performance of the 2 protocols did not differ significantly for most parameters. In eyes with mild VF loss (n = 39) diagnostic sensitivities reached 72% and 77% at specificities >= 95% using the FAST RNFLT and RNFLT protocol, respectively. Conclusions: The diagnostic accuracy of the full circle RNFLT was as good as any Stratus OCT parameter on the basis of the peripapillary RNFL thickness measurements, including localized measurements. The sensitivity was moderately high in patients with mild glaucomatous VF loss. There seems to be room for further development of OCT interpretation tools for early diagnosis of glaucomaKeywords
This publication has 12 references indexed in Scilit:
- Analysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma StagesInvestigative Opthalmology & Visual Science, 2005
- Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomographyAmerican Journal of Ophthalmology, 2005
- Comparison of three optical coherence tomography scanning areas for detection of glaucomatous damageAmerican Journal of Ophthalmology, 2004
- Sensitivity and specificity of the StratusOCT for perimetric glaucomaOphthalmology, 2004
- Diagnostic accuracy of the GDx VCC for glaucomaOphthalmology, 2004
- Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of GlaucomaArchives of Ophthalmology (1950), 2004
- Fourier Analysis of Optical Coherence Tomography and Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements in the Diagnosis of GlaucomaArchives of Ophthalmology (1950), 2003
- Nerve Fiber Layer Defects with Normal Visual FieldsOphthalmology, 1993
- An Evaluation of Optic Disc and Nerve Fiber Layer Examinations in Monitoring Progression of Early Glaucoma DamageOphthalmology, 1992
- Clinically Detectable Nerve Fiber Atrophy Precedes the Onset of Glaucomatous Field LossArchives of Ophthalmology (1950), 1991