Semiautomated Quantification of Hepatitis B Virus DNA in a Routine Diagnostic Laboratory
- 1 September 2000
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Diagnostic Laboratory Immunology
- Vol. 7 (5) , 853-855
- https://doi.org/10.1128/cdli.7.5.853-855.2000
Abstract
The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10 −4 in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.Keywords
This publication has 8 references indexed in Scilit:
- Identification of Different States of Hepatitis B Virus Infection with a Quantitative PCR AssayClinical and Diagnostic Laboratory Immunology, 2000
- Routine detection and quantification of hepatitis B virus DNA in clinical laboratories: performance of three commercial assaysJournal of Virological Methods, 2000
- Clinical evaluation and applications of the Amplicor HBV Monitor™ test, a quantitative HBV DNA PCR assayJournal of Virological Methods, 1998
- Evaluation of a new assay for HBV DNA quantitation in patients with chronic hepatitis BClinical and Diagnostic Virology, 1998
- What technique should be used for routine detection and quantification of HBV DNA in clinical samples?Journal of Virological Methods, 1997
- Performance of the automated COBAS AMPLICOR™ system for the detection of hepatitis C virus RNAClinical and Diagnostic Virology, 1997
- A distinctive property of Tth DNA polymerase: enzymatic amplification in the presence of phenol.1994
- Heat-soaked PCR: an efficient method for DNA amplification with applications to forensic analysis.1992