Non-invasive blood glucose monitoring by means of near infrared spectroscopy: investigation of long-term accuracy and stability
- 6 November 2000
- journal article
- research article
- Published by Georg Thieme Verlag KG in Experimental and Clinical Endocrinology & Diabetes
- Vol. 108 (06) , 406-413
- https://doi.org/10.1055/s-2000-8137
Abstract
Modern strategies in the treatment of Diabetes mellitus require frequent blood glucose tests. Near-infrared spectroscopy [NIR] is considered to be a method for non-invasive blood glucose testing. The present study evaluated the long-term accuracy and stability of the method. Spectra of 10 patients were recorded. An individual calibration models were calculated for each patient from spectra which were recorded at the beginning of the investigation. These models were then applied to calculate blood glucose values from spectra which were recorded 84 to 169 days later. The long-term accuracy and stability of the calibration models expressed as root mean squared error of prediction [RMSP] varied from 3.1 to 35.9 mmol/l and the error grid analysis [EGA] from 13 to 92% clinically acceptable values in zones A and B. The results of the investigation indicate that long-term monitoring of blood glocose by means of NIR-spectroscopy and individual calibration models over a period of 3 to 4 months is basically possible once long-term stability of the method will be improved. Further technological progress and a better understanding of the underlying physiological processes is necessary to achieve a level of accuracy, reliability and stability of the method as required for clinical application. Abbreviations: RMSP root mean squared error of prediction; EGA error grid analysis; LOO-CV leaving-one-out cross-validationKeywords
This publication has 8 references indexed in Scilit:
- Blood-glucose self-monitoring in insulin treated type 2 diabetes mellitus - A cross-sectional study with an intervention group1999
- Meta-Analysis of the Effect of Insulin Lispro on Severe Hypoglycemia in Patients With Type 1 DiabetesDiabetes Care, 1998
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Complications in IDDM are caused by elevated blood glucose level: The Stockholm Diabetes Intervention Study (SDIS) at 10-year follow upDiabetologia, 1996
- Measurement of glucose in diabetic subjects using noninvasive transdermal extractionNature Medicine, 1995
- Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus: a randomized prospective 6-year studyDiabetes Research and Clinical Practice, 1995
- Recent advances in amperometric glucose biosensors for in vivo monitoringPhysiological Measurement, 1995
- Lymphocytic Infundibuloneurohypophysitis as a Cause of Central Diabetes InsipidusNew England Journal of Medicine, 1993