High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MS
- 3 May 2005
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 20 (6) , 515-522
- https://doi.org/10.1039/b418258h
Abstract
Precise and accurate analysis of Hg isotope compositions in environmental samples can be an invaluable tool in investigating Hg cycles in the environment. We have developed a method for high precision Hg isotope analysis using a gold trap sample introduction system coupled to a Thermo Finnigan MC-ICP-MS. Environmental samples were pyrolyzed at high temperature and Hg released from the samples was collected in gold traps. The Hg on the gold traps was then thermally released into a sample introduction system coupled to an MC-ICP-MS. The sample introduction system extended the Hg signal duration, which would otherwise be a short transient signal if released directly into the plasma, thus significantly improving the precision and accuracy of Hg isotope measurement. Instrumental mass bias was corrected using a Tl internal isotopic standard and a “standard–sample–standard” bracketing technique. Based on the long term measurement of NIST-2225 elemental Hg standard, the external precision ranges from 44 to 109 ppm for 201Hg/202Hg and 199Hg/202Hg ratios, respectively. The average mass bias corrected Hg isotope ratios for NIST-2225 are: 198Hg/202Hg = 0.335948 ± 87 (2σ), 199Hg/202Hg = 0.567423 ± 109, 200Hg/202Hg = 0.776552 ± 93, and 201Hg/202Hg = 0.443 085 ± 44. These ratios agree within error with the IUPAC values issued in 1983, but differ significantly from the IUPAC values issued in 1997. Our data suggest that there are significant Hg isotope variations among different environmental samples. Specifically, organic samples containing predominantly methylmercury appear to be enriched in light isotopes compared with samples with inorganic Hg, suggesting that biomethylation may play an important role in Hg isotope fractionation in the environment.Keywords
This publication has 25 references indexed in Scilit:
- Analytical Methods for Non-Traditional IsotopesReviews in Mineralogy and Geochemistry, 2004
- Natural variations of Se isotopic composition determined by hydride generation multiple collector inductively coupled plasma mass spectrometryGeochimica et Cosmochimica Acta, 2002
- Comment: Variations in the isotope composition of mercury in a freshwater sediment sequence and food webCanadian Journal of Fisheries and Aquatic Sciences, 2001
- Measurement of high precision isotope ratios for mercury from coals using transient signalsJournal of Analytical Atomic Spectrometry, 2001
- Mercury abundances and isotopic compositions in the Murchison (CM) and Allende (CV) carbonaceous chondritesGeochimica et Cosmochimica Acta, 2001
- Variations in the isotope composition of mercury in a freshwater sediment sequence and food webCanadian Journal of Fisheries and Aquatic Sciences, 2001
- Abundance of zinc isotopes as a marine biogeochemical tracerGeochemistry, Geophysics, Geosystems, 2000
- Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracersChemical Geology, 2000
- Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometryChemical Geology, 1999
- Determination of lead isotope ratios by inductively coupled plasma-mass spectrometry (ICP-MS)Spectrochimica Acta Part B: Atomic Spectroscopy, 1987