Development of a new high temperature/high pressure flow system for the continuous digestion of biological samples
- 1 January 1999
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 14 (4) , 683-691
- https://doi.org/10.1039/a900634f
Abstract
The development of a new high temperature/high pressure flow system that incorporates resistively heated capillaries for the continuous digestion of various samples is presented. The system allows the continuous digestion of samples at temperatures of up to 260 °C and a pressure of up to 30 MPa (300 bar). Aqueous solutions of simple organic compounds such as glucose, as well as slurries of different biological materials, e.g., Bovine Liver, milk or juice, were digested. The determination of the residual carbon content was performed off-line by ICP-OES. Compared with other continuous flow digestion systems, unusually low residual carbon contents were obtained. For the majority of biological samples digested, the residual carbon content was 1-13%, corresponding to a digestion efficiency of 87-99%. The potential of the continuous digestion system was illustrated by the digestion of three certified reference materials (Dried Whole Animal Blood, Bovine Liver and Tomato Leaves) and subsequent determination of Mn, Cu, Zn and Fe with ICP-OES. Recoveries between 76 and 109% were found. The RSDs ranged from 2.5 (Mn in Tomato Leaves) to 15% (Fe in Dried Whole Animal Blood).Keywords
This publication has 28 references indexed in Scilit:
- In vivo sample uptake and on-line measurements of cobalt in whole blood by microwave-assisted mineralization and flow injection electrothermal atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1995
- A study of laser ablation and slurry nebulisation sample introduction for the analysis of geochemical materials by inductively coupled plasma spectrometryAnalytical and Bioanalytical Chemistry, 1990
- Characteristics of aerosols produced by the spark dischargeAnalytical Chemistry, 1989
- Laser ablation system for solid sample analysis by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1989
- Trace element analysis of biological material following pressure digestion with nitric acid-hydrogen peroxide and microwave heatingJournal of Analytical Atomic Spectrometry, 1989
- Über die Zusammensetzung des Rückstandes biologischer Materialien nach Druckaufschluß mit SalpetersäureAnalytical and Bioanalytical Chemistry, 1988
- General aspects of trace analytical methods-VI. Acid pressure decomposition in trace element analysisPublished by Walter de Gruyter GmbH ,1984
- Der Weg zu leistungsfähigen Methoden der Elementspurenanalyse in UmweltprobenAnalytical and Bioanalytical Chemistry, 1984
- Wet ashing of some biological samples in a microwave ovenAnalytical Chemistry, 1975
- Aufschlu biologischer Matrices f r die Bestimmung sehr niedriger Spurenelementgehalte bei begrenzter Einwaage mit Salpeters ure unter Druck in einem TeflongefAnalytical and Bioanalytical Chemistry, 1972