Use of the Ar2+signal as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry
- 1 January 1995
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 10 (12) , 1047-1052
- https://doi.org/10.1039/ja9951001047
Abstract
The utility of the Ar2 + signal (at mass-to-charge ratio m/z= 80) as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry (ETV–ICP-MS) is reported. Simultaneous monitoring of the argon dimer signal with the signal(s) of the analyte element(s) indicated that non-spectral interferences, caused by matrix components co-volatilizing with the analyte element(s), can strongly affect the analyte signal profiles in solid sampling ETV–ICP-MS of samples of biological or environmental origin. This observation led to a more profound understanding of why, for a given matrix, the signal profiles strongly differ from one element to another, and why, for a given element, the signal profile is seen to be strongly dependent on the matrix. These matrix effects were also observed to cause a curvature in the sample mass response curves (analyte signal intensity as a function of sample mass). It is shown that, at least in some instances, the use of the Ar2 + signal as an internal standard allows (i) this non-linearity to be corrected for and (ii) accurate analysis results to be obtained. Finally, it is demonstrated that simultaneous registration of the argon dimer and the analyte signal(s) is useful during optimization of ashing and vaporization temperatures.Keywords
This publication has 15 references indexed in Scilit:
- Solid sampling electrothermal vaporization for sample introduction in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1995
- Solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of arsenic in standard reference materials of plant originJournal of Analytical Atomic Spectrometry, 1995
- Direct analysis of solid samples by electrothermal vaporization inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1994
- Electrothermal vaporization–inductively coupled plasma mass spectrometry for the analysis of semiconductor-grade organometallic materials and process chemicalsJournal of Analytical Atomic Spectrometry, 1994
- Direct analysis of solids by ultrasonic slurry electrothermal vaporization inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Study of element distributions in weathered marble crusts using laser ablation inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Analysis of solid samples by ICP-mass spectrometryAnalytical and Bioanalytical Chemistry, 1992
- Laser Solid Sampling for Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 1991
- Laser ablation of solids for elemental analysis by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1987
- Solid sample introduction by laser ablation for inductively coupled plasma source mass spectrometryThe Analyst, 1985