Characterization of common carotid artery blood-flow waveforms in normal human subjects
- 1 January 1999
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 20 (3) , 219-240
- https://doi.org/10.1088/0967-3334/20/3/301
Abstract
Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (TRR) = 0.917 s (intra-subject standard deviation = ±0.045 s); cycle-averaged peak-velocity (VCYC) = 38.8 cm s-1 (±1.5 cm s-1); maximum systolic Vpeak = 108.2 cm s-1 (±3.8 cm s-1) at 0.152 s (±0.008 s); dicrotic notch Vpeak = 19.4 cm s-1 (±2.9 cm s-1) at 0.398 s (±0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s-1). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only TRR and VCYC of a single archetypal waveform.Keywords
This publication has 39 references indexed in Scilit:
- Determination of Duplex Doppler Ultrasound Criteria Appropriate to the North American Symptomatic Carotid Endarterectomy TrialStroke, 1996
- Flow-pressure drop measurement and calculation in a tapered femoral artery of a dogBiorheology, 1995
- Carotid Diameter and Blood Flow Velocities in Cerebral Circulation in Hypertensive PatientsStroke, 1995
- Hemodynamic Effects of Carotid Endarterectomy by Magnetic Resonance Flow QuantificationStroke, 1995
- Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults.Stroke, 1994
- Analysis of MR phase‐contrast measurements of pulsatile velocity waveformsJournal of Magnetic Resonance Imaging, 1993
- Computer-controlled flow simulator for MR flow studiesJournal of Magnetic Resonance Imaging, 1992
- Reproducibility and relation to mean heart rate of heart rate variability in normal subjects and in patients with congestive heart failure secondary to coronary artery diseaseThe American Journal of Cardiology, 1991
- A numerical analysis of steady flow in a three-dimensional model of the carotid artery bifurcationJournal of Biomechanics, 1990
- A simple, non-dimensional, normalized common carotid Doppler velocity wave-form index that identifies patients with carotid stenosis.Stroke, 1981