Design Concepts and Principle of Operation of the HeartWare Ventricular Assist System
- 1 July 2010
- journal article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 56 (4) , 285-289
- https://doi.org/10.1097/mat.0b013e3181dfbab5
Abstract
Implantable left ventricular assist devices provide circulatory support for patients at risk of death from refractory, end-stage heart failure. Rotary blood pumps have been designed for increased reliability and smaller size for use in a broader population of patients than the first-generation pulsatile devices. The design concepts and principle of operation of the HeartWare System are discussed. The HeartWare Ventricular Assist System (HVAD) is a small centrifugal flow pump with a displacement volume of 50 ml and an output capacity of 10 L/min. A unique wide-blade impeller is suspended by hybrid passive magnets and hydrodynamic forces. An integrated inflow cannula is inserted into the left ventricle and is held in position by an adjustable sewing ring; the pump is positioned in the pericardial space. The 10-mm outflow graft is anastomosed to the ascending aorta. External system components include the microprocessor-based controller, a monitor, lithium-ion battery packs, alternating current and direct current power adapters, and a battery charger. Physiologic control algorithms are incorporated for safe operation. Preclinical life cycle tests have shown the HVAD to be highly reliable. This system design offers reliability, portability, and ease of use for ambulatory patients.Keywords
This publication has 13 references indexed in Scilit:
- Microbiology of Infection in Mechanical Circulatory SupportThe International Journal of Artificial Organs, 2007
- Infections associated with ventricular assist devices: epidemiology and effect on prognosis after transplantationTransplant Infectious Disease, 2007
- Abdominal Complications of Ventricular Assist Device PlacementSurgical Infections, 2005
- Long‐Term Destination Therapy With the HeartMate XVE Left Ventricular Assist Device: Improved Outcomes Since the REMATCH StudyCongestive Heart Failure, 2005
- Left Ventricular Assist Device–Related Infection: Treatment and OutcomeClinical Infectious Diseases, 2005
- Infection in permanent circulatory support: Experience from the REMATCH trialThe Journal of Heart and Lung Transplantation, 2004
- Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantationThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Neurologic complications of the Novacor left ventricular assist deviceThe Annals of Thoracic Surgery, 2001
- Improved outcomes with an implantable left ventricular assist system: a multicenter studyThe Annals of Thoracic Surgery, 2001
- Infectious Complications Associated with Ventricular Assist SystemsAsaio Journal, 2000