Assessment of an in situ temporal calibration method for time-resolved optical tomography
- 1 January 2003
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 8 (1) , 87-92
- https://doi.org/10.1117/1.1528206
Abstract
A 32-channel time-resolved optical imaging device is developed at University College London to produce functional images of the neonatal brain and the female breast. Reconstruction of images using time-resolved measurements of transmitted light requires careful calibration of the temporal characteristics of the measurement system. Since they can often vary over a period of time, it is desirable to evaluate these characteristics immediately after, or prior to, the acquisition of image data. A calibration technique is investigated that is based on the measurement of light back-reflected from the surface of the object being imaged. This is facilitated by coupling each detector channel with an individual source fiber. A Monte Carlo model is employed to investigate the influence of the optical properties of the object on the back-reflected signal. The results of simulations indicate that their influence may be small enough to be ignored in some cases, or could be largely accounted for by a small adjustment to the calibrated data. The effectiveness of the method is briefly demonstrated by imaging a solid object with tissue-equivalent optical properties. © 2003 Society of Photo-Optical Instrumentation Engineers.Keywords
This publication has 22 references indexed in Scilit:
- Instrumentation for fast functional optical tomographyReview of Scientific Instruments, 2002
- Noninvasive Functional Imaging of Human Brain Using LightJournal of Cerebral Blood Flow & Metabolism, 2000
- A 32-channel time-resolved instrument for medical optical tomographyReview of Scientific Instruments, 2000
- Multichannel time-resolved optical tomographic imaging systemReview of Scientific Instruments, 1999
- Development of a time-domain optical mammograph and first in vivo applicationsApplied Optics, 1999
- Design and evaluation of a continuous-wave diffuse optical tomography systemOptics Express, 1999
- Time-correlated single photon counting imager for simultaneous magnetic resonance and near-infrared mammographyReview of Scientific Instruments, 1998
- Nonuniqueness in diffusion-based optical tomographyOptics Letters, 1998
- Optical imaging in medicine: I. Experimental techniquesPhysics in Medicine & Biology, 1997
- Optical imaging in medicine: II. Modelling and reconstructionPhysics in Medicine & Biology, 1997