Alternate Site Glucose Testing: A Crossover Design
- 1 February 2002
- journal article
- clinical trial
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 4 (1) , 25-33
- https://doi.org/10.1089/15209150252924058
Abstract
A crossover design study was conducted to determine if reducing pain, by using alternative sites off the finger tip, would increase testing frequency and improve clinical outcome as measured by hemoglobin A1c (HbA1c). Subjects with type 1 and type 2 diabetes tested with the FreeStyle meter (group 1) or tested with their original meter (group 2). After three months the subjects used the alternate meter. Testing frequency and blood glucose concentrations were recorded for the month before the study began and monthly thereafter. HbA1c was tested initially, at the crossover point, and at study conclusion. Insulin users increased testing frequency from 2.4 to 3.0 tests/day. Testing frequency for non–insulin users remained the same at 1.5 tests/day. Testing frequency was the same with the FreeStyle and the original meters. The average HbA1c was 7.4% (SD 1.5%) initially, 7.3% (SD 1.5%) at the crossover point, and 6.9% (SD 1.1%) at study conclusion. There was no significant difference in HbA1c measurements between meter types. Preference rankings were 76% for FreeStyle, 20% for their original meter, and 4% preferred both meters equally. This population tended to be in good glycemic control with 70% having HbA1c at ≤8.0 at study initiation. Subjects preferred testing with the FreeStyle meter (76%), but did not increase testing frequency. Study participants tended to be in good testing compliance and glycemic control with little room for improvement. A population in poor glucose control might show differences in outcome with off site monitoring.Keywords
This publication has 12 references indexed in Scilit:
- Use of an Automated Device for Alternative Site Blood Glucose MonitoringDiabetes Care, 2001
- Substance use seems to be increasing among 11 year oldsBMJ, 2000
- An open prospective randomised trial to reduce the pain of blood glucose testing: ear versus thumbBMJ, 2000
- FreeStyle™: A Small-Volume Electrochemical Glucose Sensor for Home Blood Glucose TestingDiabetes Technology & Therapeutics, 2000
- Assessment of the pain of blood-sugar testing: a randomised controlled trialThe Lancet, 1999
- Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes databaseBMJ, 1999
- The Cost to Health Plans of Poor Glycemic ControlDiabetes Care, 1997
- Patient Empowerment: Results of a randomized controlled trialDiabetes Care, 1995
- Self-Monitoring of Blood Glucose by Adults With Diabetes in the United States PopulationDiabetes Care, 1993
- Health PsychologyAnnual Review of Psychology, 1989