Cleaning of Blood-Contaminated Reprocessed Angiographic Catheters and Spinal Needles
- 1 August 2000
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 21 (8) , 499-504
- https://doi.org/10.1086/501793
Abstract
To evaluate the efficacy of a multistep cleaning method using a cleaner and a chemical disinfectant on blood-contaminated angiographic catheters and spinal needles intended to be sterilized by hydrogen peroxide gas plasma. A mixture of radiopaque iodine contrast, bovine blood (plus ethylenediaminetetraacetic acid), and a suspension of Bacillus subtilis spores was used to simulate catheterization and needle use. The mixture was a 1:1 proportion of contrast and blood, inoculated so that there was a final concentration of B subtilis spores of 1.0×106 colony-forming units (CFU)/mL. The inoculated devices were cleaned using a hydrogen peroxide solution at a concentration of 1.5±0.5 percent by weight, followed by distilled water with enzymatic detergent. After drying, the devices were sterilized with hydrogen peroxide gas plasma. The initial B subtilis spore concentration inoculated into catheters and needles varied from 2.12×104 to 2.74×107 CFU/mL. The residual load of B subtilis spores after cleaning varied from zero (no count) to a maximum of 200 CFU/device. The multistep cleaning procedure was responsible for an average 5-log10 reduction of B subtilis spores in the catheter and needle lumens. The hydrogen peroxide and enzymatic detergent aqueous solutions were shown to be efficacious when used as part of a multistep cleaning method. The low level of microbial contamination prior to sterilization with hydrogen peroxide gas plasma assured that the intended sterility assurance level was reached.Keywords
This publication has 8 references indexed in Scilit:
- Worst-case soiling levels for patient-used flexible endoscopes before and after cleaningAmerican Journal of Infection Control, 1999
- Levels of naturally occurring microorganisms on surgical instruments after clinical use and after washingAmerican Journal of Infection Control, 1999
- The Presterilization Microbial Load on Used Medical Devices and the Effectiveness of Hydrogen Peroxide Gas Plasma AgainstBacillus SubtilisSporesInfection Control & Hospital Epidemiology, 1999
- Levels of microbial contamination on surgical instrumentsAmerican Journal of Infection Control, 1998
- Natural bioburden levels detected on rigid lumened medical devices before and after cleaningAmerican Journal of Infection Control, 1997
- Disinfection and Sterilization of Patient-Care ItemsInfection Control & Hospital Epidemiology, 1996
- Comparison of Ion Plasma, Vaporized Hydrogen Peroxide, and 100% Ethylene Oxide Sterilizers to the 12/88 Ethylene Oxide Gas SterilizerInfection Control & Hospital Epidemiology, 1996
- Fever, chills, and hypotension following cardiac catheterization with single‐ and multiple‐use disposable cathetersCatheterization and Cardiovascular Diagnosis, 1983