A minimax entropy registration framework for patient setup verification in radiotherapy
- 1 January 1999
- journal article
- research article
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 4 (6) , 287-304
- https://doi.org/10.1002/(sici)1097-0150(1999)4:6<287::aid-igs1>3.0.co;2-9
Abstract
In external beam radiotherapy (EBRT), patient setup verification over the entire course of fractionated treatment is necessary for accurate delivery of a specified dose to the tumor. We are working on the development of a minimax entropy registration framework for patient setup verification using dual portal images and the treatment planning 3D CT dataset. In this paper, we present an overview of our registration framework, where an iteratively and automatically estimated segmentation of the portal image is utilized to more accurately and robustly register the portal image to the 3D treatment-planning CT data. In addition, we describe initial testing of this approach. We note that, due to low resolution and low contrast of the portal images, this registration presents a difficult problem. We also note that the registration of the images in our proposed method is guided by the bony structure visible in the portal and the 3D CT images. However, since the prostate can move with respect to the pelvic bone, we propose using ultrasound images to quantify this movement.Keywords
This publication has 17 references indexed in Scilit:
- An efficient motion estimator with application to medical image registrationMedical Image Analysis, 1998
- Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robotIEEE Transactions on Medical Imaging, 1998
- A novel approach for the registration of 2D portal and 3D CT images for treatment setup verification in radiotherapyPublished by Springer Nature ,1998
- Motion measurements in low-contrast X-ray imageryPublished by Springer Nature ,1998
- Core-based portal image registration for automatic radiotherapy treatment verificationInternational Journal of Radiation Oncology*Biology*Physics, 1995
- The effects of out-of-plane rotations on two dimensional portal image registration in conformal radiotherapy of the prostateInternational Journal of Radiation Oncology*Biology*Physics, 1995
- An image correlation procedure for digitally reconstructed radiographs and electronic portal imagesInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Radiation field edge detection in portal imagesPhysics in Medicine & Biology, 1991
- A method for the measurement of field placement errors in digital portal imagesPhysics in Medicine & Biology, 1990
- Optimization by Simulated AnnealingScience, 1983