Pulsed, single-mode cavity ringdown spectroscopy
- 20 June 1999
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (18) , 3951-3960
- https://doi.org/10.1364/ao.38.003951
Abstract
We discuss the use of single-mode cavity ringdown spectroscopy with pulsed lasers for quantitative gas density and line strength measurements. The single-mode approach to cavity ringdown spectroscopy gives single exponential decay signals without mode beating, which allows measurements with uncertainties near the shot-noise limit. The technique is demonstrated with a 10-cm-long ringdown cavity and a pulsed, frequency-stabilized optical parametric oscillator as the light source. A noise-equivalent absorption coefficient of 5 × 10-10 cm-1 Hz-1/2 is demonstrated, and the relative standard deviation in the ringdown time (στ/τ) extracted from a fit to an individual ringdown curve is found to be the same as that for an ensemble of hundreds of independent measurements. Repeated measurement of a line strength is shown to have a standard deviation <0.3%. The effects of normally distributed noise on quantities measured using cavity ringdown spectroscopy are discussed, formulas for the relative standard deviation in the ringdown time are given in the shot- and technical-noise limits, and the noise-equivalent absorption coefficient in these limits are compared for pulsed and continuous-wave light sources.Keywords
This publication has 28 references indexed in Scilit:
- Response of a ring-down cavity to an arbitrary excitationThe Journal of Chemical Physics, 1996
- The superposition principle and cavity ring-down spectroscopyThe Journal of Chemical Physics, 1996
- Laser bandwidth effects in quantitative cavity ring-down spectroscopyApplied Optics, 1996
- Trace gas detection with cavity ring down spectroscopyReview of Scientific Instruments, 1995
- Cavity ring-down spectroscopy for quantitative absorption measurementsThe Journal of Chemical Physics, 1995
- Branch intensities and oscillator strengths for the Herzberg absorption systems in oxygenCanadian Journal of Physics, 1994
- Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six, seven, and eight stretching quantaThe Journal of Chemical Physics, 1993
- Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sourcesReview of Scientific Instruments, 1988
- Experiments on 558-nm argon oxide laser systemApplied Physics Letters, 1976
- Losses Suffered by Coherent Light Redirected and Refocused Many Times in an Enclosed MediumBell System Technical Journal, 1965