Mucus transport by high-frequency nonsymmetrical oscillatory airflow
- 1 September 1988
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 65 (3) , 1203-1209
- https://doi.org/10.1152/jappl.1988.65.3.1203
Abstract
To study air-mucus interaction as a possible mechanism of tracheal mucus transport and to test the validity of using surface tracer displacement to indicate bulk mucus transport, we performed a combined experimental-theoretical study. We hypothesized that the mucus mass is moved by the difference between expiratory and inspiratory velocities. The rate of transport of a layer of simulated mucus lining the bottom of a rectangular trough was measured in two ways during oscillatory air flow. Peak velocity ratios (R) from 1.0 to 2.0, frequencies (f) between 7 and 13 Hz, and tidal volumes (VT) between 50 and 100 ml were generated by a custom-made pump. The experimental results demonstrate that measuring the displacement of a tracer deposited on the surface of the mucus layer is equivalent to measuring bulk mucus movement by weight. Moreover the measured mucus velocities (micron) correlate well with a theoretical model which predicts that micron is proportional to delta VT f1.5 (R-1). These results suggest that shearing at the air-mucus interface could be a significant factor in the enhanced tracheal mucus clearance during high-frequency chest wall oscillation.This publication has 9 references indexed in Scilit:
- Mucus clearance by two-phase gas-liquid flow mechanism: asymmetric periodic flow modelJournal of Applied Physiology, 1987
- Criteria for mucus transport in the airways by two-phase gas-liquid flow mechanismJournal of Applied Physiology, 1986
- Clearance of mucus by simulated coughJournal of Applied Physiology, 1985
- TRACHEAL MUCUS CLEARANCE IN HIGH-FREQUENCY OSCILLATION .2. CHEST WALL VERSUS MOUTH OSCILLATIONPublished by Elsevier ,1984
- Enhanced Tracheal Mucus Clearance with High Frequency Chest Wall CompressionAmerican Review of Respiratory Disease, 1983
- VENTILATION BY HIGH-FREQUENCY CHEST WALL COMPRESSION IN DOGS WITH NORMAL LUNGSPublished by Elsevier ,1983
- Resistance of mucus-lined tubes to steady and oscillatory airflowJournal of Applied Physiology, 1982
- Rheological properties of microliter quantities of normal mucusJournal of Applied Physiology, 1977
- Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is knownThe Journal of Physiology, 1955