Stroke volume measurements by electrical bioimpedance and echocardiography in healthy volunteers
- 1 November 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 18 (11) , 1274-1278
- https://doi.org/10.1097/00003246-199011000-00018
Abstract
To evaluate the validity of three equations for estimation of thoracic electrical field size in a new bioimpedance algorithm, stroke volume (SV) as calculated by these equations was compared with that calculated by Doppler echocardiography in 48 healthy volunteers, both lean and obese. When the volume of electrically paticipating tissue was estimated from body height (modified Sramek) or body height corrected for body habitus (Sramek-Bernstein), there was considerable variation between bioimpedance and Doppler stroke volumes. When the volume of electrically participating tissue was estimated from the actual measurement of the height of the thorax and the circumference at the base of the thorax, the variation in SV differences decreased substantially (Sramek equation), although still considerable for clinical use, and there was no relationship between SV thus obtained and body habitus. Analysis of calculated stroke indices derived by our Doppler echocardiographic standard, as compared with values in the literature, revealed a systematic underestimation. We conclude that the original Sramek equation systematically underestimates SV by 15% to 20%, and the modified Sramek and Sramek-Bernstein equations systematically overestimate SV in females by about 15%, but provide SV values in males in the predicted range. Further studies on the current assumption that the electrical field size is a truncated cone may improve precision of the bioimpedance method.This publication has 8 references indexed in Scilit:
- Continuous wave doppler cardiac output: Use in pediatric patients receiving inotropic supportPediatric Cardiology, 1988
- Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiographyJournal of the American College of Cardiology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Prediction of the normal blood volume. Relation of blood volume to body habitus.Circulation, 1977
- Measurement of Blood Flow through Human Abdominal Subcutaneous Fat Tissue by Local Injection of Radioactive Xenon: Preliminary ReportActa Medica Scandinavica, 1967
- Blood Flow through Human Adipose Tissue Determined with Radioactive XenonActa Physiologica Scandinavica, 1966
- DEVELOPMENT AND EVALUATION OF AN IMPEDANCE CARDIAC OUTPUT SYSTEM1966
- Changes in Cardiac Output with AgeCirculation, 1955