Continuous Viscometric Detection in Size Exclusion Chromatography
- 1 September 1988
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 11 (12) , 2571-2591
- https://doi.org/10.1080/01483918808076747
Abstract
Continuous viscometric detection is based on the measurement of pressure drop in an on-line small capillary tube in which chromatographic eluents flow at constant flow rate. This detector is always coupled with a concentration detector (usually refractometer) and located before it to avoid back pressure in the refractometer. In order to obtain reliable information for polymer samples, it is generally necessary to connect these two detectors to a computer which performs data acquisition and treatment. First, we discuss the problem of shape, geometry and dimensions of the viscometer. The typical characteristics are the result of a compromise between contradictory targets, mainly small internal volume, low shear rate and low pressure drop. It is shown that Poiseuille's laminar flow is only obtained when coiling radius of the measurement tube is greater than 6 cm, which is not the case inside the refractometer. Accordingly, two pressure transducers are necessary to eliminate pressure drop data coming from refractometer. In a second part, we show how to extract information from pressure variation data. By using concentration data, pure solvent pressure and sample pressure it is possible to calculate intrinsic viscosity extrapolated to zero concentration at each point of the chromatogram. By comparison with intrinsic viscosity of the polymer used for calibration, a correction of hydrodynamic volume according to Benoit's universal calibration leads to absolute molecular weights. In addition, for a linear polymer, the knowledge of log [η] versus log M leads to the determination of Mark-Houwink relationship coefficients. For branched polymers, viscosity laws are curved and the comparison between the linear law corresponding to the linear equivalent polymer and the experimental law allows the determination of the g' branching parameter distribution.Keywords
This publication has 10 references indexed in Scilit:
- High-temperature coupling of high-speed GPC with continuous viscometry. II. Ethylene–vinyl acetate copolymersJournal of Applied Polymer Science, 1984
- High‐temperature coupling of high‐speed GPC with continuous viscometry. I. Long‐chain branching in polyethyleneJournal of Applied Polymer Science, 1982
- Measurement of the Dead Volume between Concurrent Detectors in Gel Permeation ChromatographyJournal of Liquid Chromatography, 1982
- Performance Evaluation of a Continuous Viscometer for High Speed GPCJournal of Liquid Chromatography, 1980
- Coupling of gel permeation chromatography and automatic viscometry. application to the study of long chain branched polyethyleneEuropean Polymer Journal, 1977
- Characterization of homopolymers and copolymers by the coupling of gel permeation chromatography and automatic viscometryJournal of Applied Polymer Science, 1972
- Gel‐permeation chromatography. VII. Molecular weight detection of GPC effluentsJournal of Polymer Science Part A-1: Polymer Chemistry, 1972
- Flow of Elastic Liquids through Curved PipesNature, 1967
- A universal calibration for gel permeation chromatographyJournal of Polymer Science Part B: Polymer Letters, 1967
- Étude par chromatographie en phase liquide de polystyrènes linéaires et ramifiés de structures connuesJournal de Chimie Physique et de Physico-Chimie Biologique, 1966