Abstract
A better understanding is needed of the role of pre-analytical factors if prostate-specific antigen (PSA) is to be reliably used as a tumor marker. Reports on the analytical performance of TANDEM-R PSA (Hybritech, Inc., San Diego, CA) differ considerably with respect to detection limit and imprecision, differences that might be due (e.g.) to the use of different control matrices, to between-batch variations in reagent composition, or to nonrobustness of the assay. During nine months we determined PSA in 986 serum samples from 728 male urology patients and 54 samples from women (25 assay runs). As controls we used two serum pools with low PSA concentration and two widely used commercial controls. The within-assay CV for patients' samples was similar to that found with the commercial controls: 2.6% to 3.4% in the upper part of the normal reference interval. Precision was worse at lower concentrations (CVs 5-10% at about 0.5 micrograms/L). Imprecision tended to be higher at the end of runs. Assay drift for 100-tube runs was -4%. PSA was stable at -20 degrees C during six months. Neither the polyester polymer in SST tubes nor a hemolysate had any detectable effect on PSA values. Clinical analysis of the first 322 patients and all patients with PSA less than or equal to 0.20 micrograms/L highlighted the requirements for strict adherence to sampling instructions and to stringent quality control also at low analyte concentrations (analyte-free sera and sera with PSA concentrations 0.2-0.5 micrograms/L). Values with TANDEM-R PSA and IRMA-Count PSA (Diagnostic Products Corp., Los Angeles, CA) correlated well with no difference in detection limit or with samples from women. Within-assay precision was better with IRMA-Count PSA in the upper part of the normal reference interval and above. The designs of the two assays were compared in a format that is generally applicable for immunoassay kits (NORDKEM kit group, unpublished), and subjective impressions were recorded.This publication has 15 references indexed in Scilit:
- Prostate Specific Antigen in the Preoperative and Postoperative Evaluation of Localized Prostatic Cancer Treated with Radical ProstatectomyJournal of Urology, 1988
- Differences in Values Obtained with 2 Assays of Prostate Specific AntigenJournal of Urology, 1988
- Evaluation of a monoclonal immunoradiometric assay for prostate-specific antigen.Clinical Chemistry, 1987
- Analytical and physiological characteristics of prostate-specific antigen and prostatic acid phosphatase in serum compared.Clinical Chemistry, 1987
- Prostate-Specific Antigen as a Serum Marker for Adenocarcinoma of the ProstateNew England Journal of Medicine, 1987
- Prostate-specific antigen as a marker for prostatic cancer: a monoclonal and a polyclonal immunoassay compared.Clinical Chemistry, 1987
- Immunoelectron microscopic localization of prostatic-specific antigen in human prostate by the protein a-gold complexCancer, 1987
- Human prostate-specific antigen: structural and functional similarity with serine proteases.Proceedings of the National Academy of Sciences, 1986
- Relative Reliability of Five Serially Measured Markers for Prognosis of Progression in Prostate Cancer23JNCI Journal of the National Cancer Institute, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986