Effect of nebulised aerosol size on lung deposition in patients with mild asthma.
Open Access
- 1 March 1987
- Vol. 42 (3) , 190-194
- https://doi.org/10.1136/thx.42.3.190
Abstract
A radioaerosol technique has been used to investigate whether the size distribution of aerosols released from a jet nebuliser affects the amount of aerosol delivered to the lungs. Six subjects with mild asthma (FEV1 81% of predicted) were studied on three occasions. On each visit they received one of three aerosols tagged with technetium-99m in 0.9% saline. The aerosols were generated by either (A) a Turret nebuliser operated at 8 l min-1 (mass median diameter (MMD) 1.8 micron); (B) an Upmist nebuliser operated at 6 l min-1 (MMD 4.6 microns); or (C) an Inspiron Mini-neb operated at 4 l min-1 (MMD 10.3 microns). The aerosols were given in a randomised single blind manner and inhaled under identical conditions of inspiratory volume and frequency. The mean (SD) percentage of aerosols A, B, C released from the nebulisers during inhalation that was recovered in an expiratory filter was 23 (6), 25 (4), and 24 (4) respectively. Of the aerosols released from the nebuliser and deposited in the body, the percentage deposited in the lung was 79 (3) for aerosol A, 59 (4) for aerosol B, and 44 (5) for aerosol C. The remaining aerosol was deposited in the oropharynx and swallowed. It is concluded that small nebulised aerosols (MMD less than 2 microns) deliver a larger dose to the lungs and should be used to maximise lung deposition.This publication has 18 references indexed in Scilit:
- A comparative study of two doses of salbutamol nebulized at 4 and 8 litres per minute in patients with chronic asthmaRespiratory Medicine, 1986
- Is driving gas flow rate clinically important for nebulizer therapy?Respiratory Medicine, 1986
- Effect of aerosol particle size on bronchodilatation with nebulised terbutaline in asthmatic subjects.Thorax, 1986
- Audit of nebuliser usePostgraduate Medical Journal, 1985
- Is the flow rate used to drive a jet nebuliser clinically important?BMJ, 1985
- Dosage and delivery of nebulised beta agonists in hospital.Thorax, 1983
- Effect of aerosol and oral fenoterol on histamine and methacholine challenge in asthmatic subjects.Thorax, 1981
- Standardization of inhalation provocation tests: Influence of nebulizer output, particle size, and method of inhalationJournal of Allergy and Clinical Immunology, 1981
- Lung clearance of soluble radioaerosols of different molecular weights in systemic sclerosis.Thorax, 1979
- Effect of lung function and mode of inhalation on penetration of aerosol into the human lung.Thorax, 1977