Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans
Open Access
- 1 November 1999
- journal article
- research article
- Published by Wiley in The Journal of Physiology
- Vol. 521 (1) , 273-287
- https://doi.org/10.1111/j.1469-7793.1999.00273.x
Abstract
1. Under conditions of both euoxia and hypoxia, it is generally accepted that the ventilatory response to CO2 has both rapid (peripheral chemoreflex) and slow (central chemoreflex) components. However, under conditions of hyperoxia, it is unclear in humans whether the fast component is completely abolished or merely attenuated in magnitude. 2. The present study develops a technique to determine whether or not a two-compartment model fits the ventilatory response to CO2 significantly better than a one-compartment model. Data were collected under both hypoxic (end-tidal PO2 = 50 Torr) conditions, when two components would be expected, and under hyperoxic (end-tidal PO2 = 200 Torr) conditions, when the presence of the fast compartment is under question. 3. Ten subjects were recruited, of whom nine completed the study. The end-tidal PCO2 of each subject was varied according to a multi-frequency binary sequence that involved 13 steps into and 13 steps out of hypercapnia lasting altogether 1408 s. 4. In four out of nine subjects in hypoxia, and six out of nine subjects in hyperoxia, the two-compartment model fitted the data significantly better than the one-compartment model (F ratio test on residuals). This improvement in fit was significant for the pooled data in both hypoxia (P < 0.05) and hyperoxia (P < 0.005). Mean ventilatory sensitivities for the central chemoreflex were (mean +/- s.e.m.) 1. 69 +/- 0.39 l min-1 Torr-1 in hypoxia and 2.00 +/- 0.32 l min-1 Torr-1 in hyperoxia. Mean ventilatory sensitivities for the peripheral chemoreflex were 2.42 +/- 0.36 l min-1 Torr-1 in hypoxia and 0.75 +/- 0.16 l min-1 Torr-1 in hyperoxia. 5. It is concluded that the rapid and slow components of the ventilatory response to CO2 can be separately identified, and that a rapid component persists under conditions of hyperoxia.Keywords
This publication has 31 references indexed in Scilit:
- Nature of the interaction between central and peripheral chemoreceptor drives in human subjectsCanadian Journal of Physiology and Pharmacology, 1996
- Nature of the interaction between central and peripheral chemoreceptor drives in human subjectsCanadian Journal of Physiology and Pharmacology, 1996
- An assessment of central‐peripheral ventilatory chemoreflex interaction using acid and bicarbonate infusions in humans.The Journal of Physiology, 1995
- An assessment of central-peripheral ventilatory chemoreflex interaction in humansRespiration Physiology, 1992
- Hypoxic depression of ventilation in humans: alternative models for the chemoreflexesRespiration Physiology, 1990
- Influence of peripheral O2 tension on the ventilatory response to CO2 in catsRespiration Physiology, 1983
- Stimulus interaction in the responses of carotid body chemoreceptor single afferent fibersRespiration Physiology, 1975
- The transient respiratory effects in man of sudden changes in alveolar CO2, in hypoxia and in high oxygenRespiration Physiology, 1974
- Effect of hypoxia on carotid chemoreceptor response to carbon dioxide in catsRespiration Physiology, 1971
- THE RELATION BETWEEN ALVEOLAR OXYGEN PRESSURE AND THE RESPIRATORY RESPONSE TO CARBON DIOXIDE IN MANQuarterly Journal of Experimental Physiology and Cognate Medical Sciences, 1958