An ergonomic evaluation of dexterity and tactility with increase in examination/surgical glove thickness
- 1 April 1995
- journal article
- clinical trial
- Published by Taylor & Francis in Ergonomics
- Vol. 38 (4) , 723-733
- https://doi.org/10.1080/00140139508925144
Abstract
Latex gloves of five different thicknesses (0·21 mm, 0·51 mm, 0·65 mm, 0·76 mm, and 0·83 mm) were manufactured in-house and tested for dexterity and tactility; dexterity and tactility measures with the bare hand were used as control values. Fifteen adult males (mean age = 22·8 years, mean stature = 179 cm, mean body weight = 75·4 kg, mean palm width = 9·9 cm, mean palm depth = 10·9 cm, and mean middle finger length = 9 cm) and five adult females (mean age = 21·2 years, mean stature = 168 cm, mean body weight = 53·6 kg, mean palm width = 8 cm, mean palm depth = 8 cm, and mean middle finger length = 8·3 cm) voluntarily participated. The gloves also were tested for punctures resulting from impact forces encountered during routine hand movements. The results indicated that the latex glove with 0·83 mm thickness successfully resisted routine impact forces and at the same time provided dexterity and tactility comparable to the bare hand. Thinner gloves failed the impact test and punctured. This indicates that it is possible to greatly reduce the incidence of exposure to contaminated body fluids through accidental needlesticks without compromising the preferred hand's capabilitiesKeywords
This publication has 8 references indexed in Scilit:
- A quantitative evaluation of gloves used with non-powered hand tools in routine maintenance tasksErgonomics, 1994
- Occult Surgical Glove Perforations in Otolaryngology--Head and Neck SurgeryJAMA Otolaryngology–Head & Neck Surgery, 1991
- The effectiveness of double-gloving in otolaryngologyClinical Otolaryngology, 1990
- Latex and vinyl examination gloves. Quality control procedures and implications for health care workersArchives of internal medicine (1960), 1989
- Failure of gloves and other protective devices to prevent transmission of hepatitis B virus to oral surgeonsJAMA, 1988
- Risk to surgeons: A survey of accidental injuries during operationsBritish Journal of Surgery, 1988
- Surgical gloves as a mechanical barrier against human immunodeficiency virusesBritish Journal of Surgery, 1988
- A Biomechanical ScissorsProceedings of the Human Factors Society Annual Meeting, 1975