To assess the accuracy of computer-aided surgery for common neurotologic approaches to the temporal bone. Cadaveric heads were dissected by using standard neurotologic approaches to the temporal bone including translabyrinthine, middle fossa, and retrosigmoid. Dissected anatomic landmarks from each approach were compared with CT images that were obtained before dissection on the VectorVision 2 system (BrainLAB Corp, Munich, Germany) and the variability measured from digital images. Each approach was performed 5 times, with each anatomic landmark measured 3 times from each approach. The accuracy of the computer-aided surgery system was less than 1 mm for all anatomic points measured. Forty-two of the 49 measured points were accurate to less than 0.5 mm. Computer-aided surgery of the temporal bone using common neurotologic approaches can be performed accurately and reliably in cadaver specimens. The utility and limitations of computer-aided surgery in the temporal bone are discussed. B-2.Keywords
This publication has 10 references indexed in Scilit:
- Headset-Related Sensory and Motor Neuropathies in Image-Guided Sinus SurgeryJAMA Otolaryngology–Head & Neck Surgery, 2002
- Error Analysis in Cranial Neuronavigationmin - Minimally Invasive Neurosurgery, 2002
- Presigmoid Approach for Cavernous Angioma in the Pons. Technical Note.Neurologia medico-chirurgica, 2002
- Stereotactic Computer-Assisted Navigational Sinus Surgery: Historical Perspective and Review of the Available SystemsThe Journal of Otolaryngology, 2001
- Brain Lab VectorVision Neuronavigation System: Technology and Clinical Experiences in 131 CasesNeurosurgery, 1999
- The Operating Microscope Guided by a Neuronavigation System: A Technical Notemin - Minimally Invasive Neurosurgery, 1998
- Utility of Frameless Stereotaxy in the Resection of Skull Base and Basal Cerebral Lesions in ChildrenJournal of Neurological Surgery Part B: Skull Base, 1998
- Use of Cranial Surface Anatomic Fiducials for Interactive Image-guided Navigation in the Temporal Bone: A Cadaveric StudyNeurosurgery, 1997
- In Vivo Accuracy Testing and Clinical Experience with the ISG Viewing WandNeurosurgery, 1996
- Intra-operative image guidance in otolaryngology – The use of the ISG viewing wandThe Journal of Laryngology & Otology, 1996