To develop a valid, reliable, and responsive bedside instrument assessing Adaptation to the Intensive Care Environment (ATICE) in mechanically ventilated adult intensive care unit (ICU) patients. Instrument development and prospective clinimetric evaluation. University-affiliated medical ICU. Consecutive patients with expected mechanical ventilation of >/=12 hrs. Administration of ATICE. Item generation for the ATICE involved focus groups and literature review. The ATICE consists of five items: Awakeness and Comprehension combined in a Consciousness domain, and Calmness, Ventilator Synchrony, and Face Relaxation combined in a Tolerance domain. Clinical sensibility of the ATICE assessed by ten ICU physicians and 20 ICU nurses not involved in the development of the ATICE was rated highly (median values 5-7 on a 7-point scale). The ATICE was administered to 80 patients during a total of 152 assessments. Each assessment was performed by three raters (ICU physician, ICU nurse, research nurse), concomitantly with independent scoring of four scales (Ramsay Scale, Riker Scale, Glasgow Coma Scale, and Comfort Scale) and six visual analog scales. Internal consistency was high, as reflected by Cronbach's alpha for the Consciousness and Tolerance domains of .87 and .67, respectively. Intraclass correlation coefficients for the Consciousness and the Tolerance domains ranged from .92 to .99, indicating high interrater reliability. Cross-sectional and longitudinal validity was confirmed for the overall ATICE and the Consciousness and Tolerance domains, as reflected by strong correlations between ATICE and the relevant items or domains of the Ramsay Scale, Riker Scale, Glasgow Coma Scale, Comfort Scale, each of the visual analog scales, and the amounts of sedatives and analgesics administered. The ATICE measures the adaptation of mechanically ventilated patients to the ICU environment. After rigorous multidisciplinary development, we demonstrated high reliability, validity, and responsiveness of this instrument.Keywords
This publication has 34 references indexed in Scilit:
- Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adultCritical Care Medicine, 2002
- Measuring quality of sedation in adult mechanically ventilated critically ill patients: the Vancouver Interaction and Calmness ScaleJournal of Clinical Epidemiology, 2000
- Using and understanding sedation scoring systems: a systematic reviewIntensive Care Medicine, 2000
- Acquired neuromuscular disorders in critically ill patients: a systematic reviewIntensive Care Medicine, 1998
- Incidence of and Risk Factors for Ventilator-Associated Pneumonia in Critically Ill PatientsAnnals of Internal Medicine, 1998
- The Use of Continuous IV Sedation Is Associated With Prolongation of Mechanical VentilationChest, 1998
- Continuous infusion of haloperidol controls agitation in critically ill patientsCritical Care Medicine, 1994
- Critical illness polyneuropathy a review of the literature, definition and pathophysiologyClinical Neurology and Neurosurgery, 1994
- Assessing Distress in Pediatric Intensive Care Environments: The COMFORT ScaleJournal of Pediatric Psychology, 1992
- Controlled Sedation with Alphaxalone-AlphadoloneBMJ, 1974