Nonlinear Theory of Turboalternators Part II. Load Dependent Synchronous Reactances
- 1 March 1973
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. PAS-92 (2) , 592-599
- https://doi.org/10.1109/tpas.1973.293762
Abstract
The method in Ref. [1] is used to determine synchronous reactances for the turbogenerator at operating conditions in Part I [2]. The influence of saturation on the direct and quadrature reactances is studied and the difficulties caused by linear parameters in nonlinear theory are discussed. A modified phasor-diagram taking the small angles dγ and γq into account is developed. The results are given for a Westinghouse Electric Corp. 200 MVA, 15 kV, wye-connected, four-pole, 50 Hz generator. Available test data are compared with computations.Keywords
This publication has 7 references indexed in Scilit:
- Determination of Waterwheel Alternator Steady-State Reactances from Flux PlotsIEEE Transactions on Power Apparatus and Systems, 1972
- Determination of Waterwheel Alternator Transient Reactances from Flux PlotsIEEE Transactions on Power Apparatus and Systems, 1972
- Finite-Element Analysis of Magnetically Saturated D-C MachinesIEEE Transactions on Power Apparatus and Systems, 1971
- Analysis of Turboalternator Magnetic Fields by Finite ElementsIEEE Transactions on Power Apparatus and Systems, 1971
- Finite Element Solution of Saturable Magnetic Field ProblemsIEEE Transactions on Power Apparatus and Systems, 1970
- Representation of the Magnetization Characteristic of DC Machines for Computer UseIEEE Transactions on Power Apparatus and Systems, 1968
- Calculation of Synchronous Machine Constants- Reactances and Time Constants Affecting Transient CharacteristicsTransactions of the American Institute of Electrical Engineers, 1931