An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics
- 1 February 2004
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 15 (2) , 212-232
- https://doi.org/10.1016/j.jasms.2003.09.008
Abstract
We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1–5% deviation in uncorrected elution times), repeatability (105 for peptide abundances in the overall separation.Keywords
This publication has 57 references indexed in Scilit:
- Comparison of in‐gel and on‐membrane digestion methods at low to sub‐pmol level for subsequent peptide and fragment‐ion mass analysis using matrix‐assisted laser‐desorption/ionization mass spectrometryElectrophoresis, 1997
- Masses of stable neon isotopes determined at parts per billion precision by Fourier transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Radial ion transport due to resistive-wall destabilization in Fourier transform mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- The ‘infinity cell’: A new trapped‐ion cell with radiofrequency covered trapping electrodes for fourier transform ion cyclotron resonance mass spectrometryJournal of Mass Spectrometry, 1991
- Ion trapping and manipulation in a tandem time-of-flight-Fourier transform mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1991
- A high Pressure external ion source for fourier transform ion cyclotron resonance spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1990
- Suspended trapping procedure for alleviation of space charge effects in gas chromatography/Fourier-transform mass spectrometryAnalytical Chemistry, 1990
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- {BLR 400} Legislation - U.S. Congress - Patent - RegulationPublished by Mary Ann Liebert Inc ,1985
- Das elektrische Massenfilter als Massenspektrometer und IsotopentrennerZeitschrift für Physik, 1958