Double Pass Linear Accelerator - Reflexotron
- 1 June 1975
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 22 (3) , 1060-1064
- https://doi.org/10.1109/tns.1975.4327808
Abstract
Measurements of energy spectra and percentage beam transmissions are given for an S-band linear accelerator through which the electron beam passes twice, in opposite directions. Results are presented for two magnet reflecting systems which have energy acceptance windows, ΔE/E, of 2% and 16% where E is the output beam energy after the first pass through the accelerator. For a first pass beam energy of 8 MeV the second pass energy could be varied from 3 MeV to 16 MeV by changing the separation between the accelerator and the magnet system. The corresponding full-width half-maximum energy spreads were 1.6 MeV and 0.7 MeV respectively. The system transmission was 35% first pass (unbunched injected beam) and ~ 100% second pass.Keywords
This publication has 2 references indexed in Scilit:
- Energy accumulation of heavy ions by multiple traversal through a single tandem acceleratorNuclear Instruments and Methods, 1966
- The microtron as a high-energy, high current particle acceleratorAnnals of Physics, 1958