Coronary Thermodilution to Assess Flow Reserve
Top Cited Papers
Open Access
- 28 May 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 105 (21) , 2482-2486
- https://doi.org/10.1161/01.cir.0000017199.09457.3d
Abstract
Background — Guide wire–based simultaneous measurement of fractional flow reserve (FFR) and coronary flow reserve (CFR) is important to understand microvascular disease of the heart. The aim of this study was to investigate the feasibility of simultaneous measurement of FFR and CFR by one pressure-temperature sensor-tipped guide wire with the use of coronary thermodilution and to compare CFR by thermodilution (CFR thermo ) with simultaneously measured Doppler CFR (CFR Doppl ). Methods and Results — In 103 coronary arteries in 50 patients, a pressure-temperature sensor-tipped 0.014-inch floppy guide wire and a 0.014-inch Doppler guide wire were introduced. Both normal vessels and a wide range of stenotic vessels were included. With 3 mL of saline at room temperature used as an indicator, by hand-injection, thermodilution curves in the coronary artery were obtained in triplicate, both at baseline and at intravenous adenosine-induced maximum hyperemia. After adequate curve-fitting, CFR thermo was calculated from the ratio of inverse mean transit times and compared with CFR Doppl calculated by velocities at hyperemia and baseline. Adequate sets of thermodilution curves and corresponding CFR thermo could be obtained in 87% of the arteries versus 91% for Doppler CFR and 100% for FFR. CFR thermo correlated fairly well to CFR Doppl (CFR thermo =0.84 CFR Doppl +0.17; r =0.80; P 20% between both indexes were seen in a quarter of all arteries. Conclusions — This study shows the feasibility of simultaneous measurement of FFR (by coronary pressure) and CFR (by coronary thermodilution) in humans by one single guide wire in a practical and straightforward way and will facilitate assessment of microvascular disease.Keywords
This publication has 7 references indexed in Scilit:
- Fractional Flow Reserve in Patients With Prior Myocardial InfarctionCirculation, 2001
- Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurementsJournal of the American College of Cardiology, 1998
- From Research to Clinical Practice: Current Role of Intracoronary Physiologically Based Decision Making in the Cardiac Catheterization LaboratoryJournal of the American College of Cardiology, 1997
- Clinical, Angiographic and Hemodynamic Predictors of Recruitable Collateral Flow Assessed During Balloon Angioplasty Coronary OcclusionJournal of the American College of Cardiology, 1997
- Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery StenosesNew England Journal of Medicine, 1996
- Thermal detection of cellular infiltrates in living atherosclerotic plaques: possible implications for plaque rupture and thrombosisThe Lancet, 1996
- Coronary artery flow monitoring following coronary interventionsThe American Journal of Cardiology, 1993