Random Signal Method of Nonlinear Amplitude Distortion Measurement
- 1 May 1971
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. IM-20 (2) , 95-99
- https://doi.org/10.1109/tim.1971.5570700
Abstract
The degree and orders of nonlinearity of a system can be determined by the use of a random test signal. A Gaussian-distributed random signal with a uniform power spectral density except for a narrow spectral notch is used as an input test signal. The power within the notch at the system output is a measure of the degree of system nonlinearity. Relative variations of the output power within the notch with input loading identify the orders of nonlinearity.Keywords
This publication has 1 reference indexed in Scilit: