Experimental Cryoapplication with Variations in the Pressure Exerted on the Sclera
- 1 January 1972
- journal article
- Published by S. Karger AG in Ophthalmic Research
- Vol. 3 (3) , 129-144
- https://doi.org/10.1159/000266186
Abstract
Study of cryolesions produced by varying pressures exerted on rabbit sclera with a constant temperature of ––79 C and an application time of 5 seconds. The histological sections were studied 4 h, 4 days, 1 week and 1 month after cryoapplication. Significant differences were produced in lesion intensity when scleral pressures of 36, 70, 110 and 165 g were used. Optimal adhesion without deleterious side-effects was obtained on attached rabbit retinas with a pressure of 70 g.Keywords
This publication has 0 references indexed in Scilit: