Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
- 1 November 1996
- journal article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 34 (6) , 409-419
- https://doi.org/10.1007/bf02523843
Abstract
The selected ion flow tube (SIFT) technique for trace gas analysis of air and breath is based on soft chemical ionisation of the trace gases to the exclusion of the major air and breath gases, in fast-flowing inert carrier gas, exploiting the ion-molecule reactions that occur between the trace gases and the pre selected precursor ions (H3O+, NO+ and O 2 + ). The physics and ion chemistry involved in the SIFT technique are described, as are the kinetics of the ion-molecule reactions that are exploited to quantitatively analyse the trace gases. Fast on-line data-acquisition hardware and software have been developed to analyse the mass spectra obtained, from which partial pressures of the trace gases down to about 10 parts per billion can be measured. The time response of the instrument is 20 ms, allowing the profiles of the trace gas concentrations on breath to be obtained during a normal breathing cycle. Pilot results obtained with this SIFT technique include detection and quantification of the most abundant breath trace gases, analysis of cigarette smoke, detection of gases present on smokers' breath and accurate measurement of the partial pressures of NH3, NO and NO2 in air. The simultaneous analysis of several breath trace gases during a single exhalation is clearly demonstrated, and thus different elution times for isoprene and methanol along the respiratory tract are observed. This technique has great potential in many clinical and biological disciplines, and in health and safety monitoring.Keywords
This publication has 24 references indexed in Scilit:
- Validation of the SIFT technique for trace gas analysis of breath using the syringe injection techniqueAnnals of Occupational Hygiene, 1997
- Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air and on breathInternational Reviews in Physical Chemistry, 1996
- A selected ion flow tube study of the reactions of NO+ and O+2 ions with some organic molecules: The potential for trace gas analysis of airThe Journal of Chemical Physics, 1996
- Reactions of Hydrated Hydronium Ions and Hydrated Hydroxide Ions with Some Hydrocarbons and Oxygen-Bearing Organic MoleculesThe Journal of Physical Chemistry, 1995
- Reactions of H3O+ and OH− ions with some organic molecules; applications to trace gas analysis in airInternational Journal of Mass Spectrometry and Ion Processes, 1995
- Transport Properties of Gaseous Ions over a Wide Energy Range, IVAtomic Data and Nuclear Data Tables, 1995
- Increased nitric oxide in exhaled air of normal human subjects with upper respiratory tract infectionsEuropean Respiratory Journal, 1995
- Applications of proton transfer reactions to gas analysisInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Studies of interstellar ion reactions using the SIFT technique: isotope fractionationAccounts of Chemical Research, 1992
- Elementary interactions between charged and neutral species in plasmasPublished by Walter de Gruyter GmbH ,1984