Effect of scleral recording location on ERG amplitude
- 1 January 1986
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 5 (12) , 959-965
- https://doi.org/10.3109/02713688608995177
Abstract
The isolated arterially perfused eye preparation has become a valuable tool in the investigation of ocular function. Normal retinal function can be maintained for several hours with the measurement of the gross electroretinogram (ERG) serving as a useful monitor of the electrophysiological condition of the preparation. This paper deals with the manner in which the amplitude of the ERG is affected by the electrode recording locations and describes the characteristic distribution of potentials on the surface of the isolated arterially perfused dog eye. The ERG is recorded between a fixed corneal contact lens electrode and a movable electrode on the uppermost surface of the sclera. The scleral electrode is moved in small increments parallel to the optic axis and lowered onto the uppermost surfaces of the sclera on a line from the corneal limbus to the optic nerve. The resulting ERG profile is characterised by minimal b-wave amplitude at the corneal limbus and little growth until a point 5 or 6 mm from the corneal limbus is reached, followed by a region of rapidly increasing amplitude up to a maximum at the point where the optic nerve exists from the globe. There follows a region of large but stable signal amplitude along the optic nerve. The ERG profile is largely unaffected by a reorientation of the globe about the optic axis, demonstration that the potential distribution on the surface of the globe may be described in terms of points equidistant from the limbus being isopotential. A similar distribution of potentials is shown to exist with two types of retinal illumination, that from a simple flash lamp and that from a more uniform retinal stimulation provided by the incorporation of a ganzfeld sphere. The implications of this finding are discussed with reference to clinical and experimental electroretinography.This publication has 12 references indexed in Scilit:
- Vitreal oxygen tension gradients in the isolated perfused cat eyeCurrent Eye Research, 1986
- The Canine c-Wave: Breed and Anesthetic-Dependent VariationsDocumenta Ophthalmologica Proceedings Series, 1983
- Neurobiology of perfused mammalian eyesJournal of Neuroscience Methods, 1981
- Some characteristics of the c-wave of ERGs recorded by a pair of electrodes on the cornea and scleraAlbrecht von Graefes Archiv für Ophthalmologie, 1977
- The function of the retina in the perfused eyeDocumenta Ophthalmologica, 1975
- A Full-Field System for Clinical ElectroretinographyArchives of Ophthalmology (1950), 1974
- Electrophysiological Application of the Living Extracorporeal Bovine EyePublished by Springer Nature ,1972
- The role of neural mechanisms in the regulation of intraocular pressure in the catExperimental Neurology, 1960
- Acetazolamide and the Venous Pressure of the EyeArchives of Ophthalmology (1950), 1960
- ON THE POTENTIAL FIELD OF THE RABBIT ELECTRORETINOGRAMActa Ophthalmologica, 1958