Aortic valve pressure gradients in patients with aortic valve stenosis: quantification with velocity-encoded cine MR imaging.

Abstract
Pressure gradients across the aortic valve due to stenosis of the valve must be measured accurately to evaluate the functional severity of the stenosis. Velocity-encoded cine MR has been used to quantify blood flow and flow direction and, more recently, the regurgitant fraction in aortic regurgitation. The purpose of this study was to determine the feasibility and accuracy of velocity-encoded cine MR for estimating pressure gradients across the aortic valve in patients with aortic stenosis.We used velocity-encoded cine MR to measure flow velocity and determine pressure gradients across the aortic valve in 19 subjects. The pressure gradient (delta P) was estimated from the simplified Bernoulli equation by using the maximum instantaneous aortic jet velocity (Vmax): delta P (mm Hg) = 4V2max (m/sec).Maximum and mean systolic pressure gradients determined by using velocity-encoded cine MR were 3-148 mm Hg and 2-87 mm Hg, respectively, for all subjects. The pressure gradients correlated closely with gradients d...