Miniature High Temperature Laminar Diffusion Flames for Analytical Atomic Spectrometry
- 1 January 1981
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 35 (1) , 26-35
- https://doi.org/10.1366/0003702814731941
Abstract
Miniature high temperature laminar diffusion flames are described for analytical atomic spectrometry. Fuel flow rates below 0.2 liters/min are used and temperatures in excess of 2500 K are maintained in a stable, fuel-rich combustion environment of low background emission. The internal atomizer chamber volume is 1.5 ml (below the burner top). A graphite cup atomizer is used for sample introduction and is “fired” inside the miniature burner head in the presence of “fuel only.” Oxidant diffuses into the fuel zone above the burner top. Compared to conventional electrothermal atomizers, the miniature N2O → H2 diffusion flame greatly reduced particulate light scattering in continuum excited atomic fluorescence spectrometry. In atomic absorption spectrometry, the hot miniature flame serves to effectively reduce the molecular spectral interference due to gaseous diatomic alkali halides. The enhanced gas phase concentration of atomic products presently results in a concentration sensitivity improvement of 30 times over conventional premixed flames used in Eimac continuum excited atomic fluorescence. The improvement in absolute weight sensitivity is 140 times for atomic fluorescence.Keywords
This publication has 26 references indexed in Scilit:
- Investigation into the Operating Characteristics of a “Microarc” Atmospheric-Pressure Glow DischargeApplied Spectroscopy, 1979
- Molecular absorption spectra of complex matrices in premixed flamesAnalytical Chemistry, 1979
- Optical emission spectrometry with an inductively coupled radiofrequency argon plasma source and sample introduction with a graphite rod electrothermal vaporisation device. Part I. Instrumental assembly and performance characteristicsThe Analyst, 1978
- LXXXVI. Atomic spectroscopy atomization systems (Continued)Journal of Chemical Education, 1975
- Determination of lithium in microliter samples of blood serum using flame atomic emission spectrometry with a tantalum filament vaporizerAnalytical Chemistry, 1975
- Inductively coupled plasma-optical emission analytical spectroscopy. Tantalum filament vaporization of microliter samplesAnalytical Chemistry, 1974
- An Instrument for Simultaneous Determination of Sodium and Potassium in Microsamples of Biological MaterialActa Physiologica Scandinavica, 1967
- An integrating flame photometer for simultaneous microanalysis of sodium and potassium in biological fluidsAnalytical Biochemistry, 1967
- The determination of sodium and potassium in biological fluids with the dual channel ultramicro flame photometerAnalytical Biochemistry, 1960
- An integrating flame photometer for small quantitiesJournal of Scientific Instruments, 1951