Microvascular Po2during extreme hemodilution with hemoglobin site specifically PEGylated at Cys-93(β) in hamster window chamber
Open Access
- 1 October 2004
- journal article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 287 (4) , H1609-H1617
- https://doi.org/10.1152/ajpheart.00146.2004
Abstract
The oxygen transport capacity of nonhypertensive polyethylene glycol (PEG)-conjugated hemoglobin solutions were investigated in the hamster chamber window model. Microvascular measurements were made to determine oxygen delivery in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Two isovolemic hemodilution steps were performed with a 6% Dextran 70 (70-kDa molecular mass) plasma expander until Hct was 35% of control. Isovolemic blood volume exchange was continued using two surface-modified PEGylated hemoglobins (P5K2, P50= 8.6, and P10K2, P50= 8.3; P50is the hemoglobin Po2corresponding to its 50% oxygen saturation) until Hct was 11%. P5K2 and P10K2 are PEG-conjugated hemoglobins that maintain most of the hemoglobin allosteric properties and have a cooperativity index of n = 2.2. The effects of these molecular solutions were compared with those obtained in a previous study using MP4, a PEG-modified hemoglobin whose P50was 5.4 and cooperativity was 1.2 (Tsai et al., Am J Physiol Heart Circ Physiol 285: H1411–H1419, 2003). Tissue oxygen levels were higher after P5K2 (7.0 ± 2.5 mmHg) and P10K2 (6.3 ± 2.3 mmHg) versus MP4 (1.7 ± 0.5 mmHg) or the nonoxygen carrier Dextran 70 (1.3 ± 1.2 mmHg). Microvascular oxygen delivery was higher after P5K2 and P10K2 (2.22 and 2.34 ml O2/dl blood) compared with MP4 (1.41 ml O2/dl blood) or Dextran 70 (0.90 ml O2/dl blood); however, all these values were lower than control (7.42 ml O2/dl blood). The total hemoglobin in blood was similar in all cases; therefore, the improvement in tissue Po2and oxygen delivery appears to be due to the increased cooperativity of the new molecules.Keywords
This publication has 26 references indexed in Scilit:
- Microvascular oxygen distribution in awake hamster window chamber model during hyperoxiaAmerican Journal of Physiology-Heart and Circulatory Physiology, 2003
- Site-Specific PEGylation of Hemoglobin at Cys-93(β): Correlation between the Colligative Properties of the PEGylated Protein and the Length of the Conjugated PEG ChainBioconjugate Chemistry, 2003
- Hemoglobin–Oxygen Equilibrium Curves Measured during Enzymatic Oxygen ConsumptionAnalytical Biochemistry, 1998
- Interstitial pH and pO2 gradients in solid tumors in vivo: High-resolution measurements reveal a lack of correlationNature Medicine, 1997
- Microcirculatory Consequences of Blood Substitution with αα-HemoglobinPublished by Springer Nature ,1995
- Autoregulation of blood flow.Circulation Research, 1986
- Technical report—a new chamber technique for microvascular studies in unanesthetized hamstersZeitschrift für Die Gesamte Experimentelle Medizin, 1980
- Application of the “two-slit” photometric technique to the measurement of microvascular volumetric flow ratesMicrovascular Research, 1978
- Capillary flow velocity measurements in vivo and in situ by television methodsMicrovascular Research, 1975
- Autoregulatory Responses of Cat Mesenteric Arterioles Measured in VivoCirculation Research, 1968