Acute In Vivo Evaluation of an Implantable Continuous Flow Biventricular Assist System
- 1 January 2008
- journal article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 54 (1) , 20-24
- https://doi.org/10.1097/mat.0b013e31815b2d1e
Abstract
An implantable biventricular assist device offers a considerable opportunity to save the lives of patients with combined irreversible right and left ventricular failure. The purpose of this study was to evaluate the hemodynamic and physiologic performance of the combined implantation of the CorAide™ left ventricular assist device (LVAD) and the DexAide right ventricular assist device (RVAD). Acute hemodynamic responses were evaluated after simulating seven different physiological conditions in two calves. Evaluation was performed by fixing the speed of one individual pump and increasing the speed of the other. Under all conditions, increased LVAD or RVAD speed resulted in increased pump flow. The predominant pathophysiologic effect of independently varying DexAide and CorAide pump speeds was that the left atrial pressure was very sensitive to increasing RVAD speed above 2,400 rpm, whereas the right atrial pressure demonstrated much less sensitivity to increasing LVAD speed. An increase in aortic pressure and RVAD flow was observed while increasing LVAD speed, especially under low contractility, ventricular fibrillation, high pulmonary artery pressure, and low circulatory blood volume conditions. In conclusion, a proper RVAD-LVAD balance should be maintained by avoiding RVAD overdrive. Additional studies will further investigate the performance of these pumps in chronic animal models.Keywords
This publication has 19 references indexed in Scilit:
- Does Total Implantability Reduce Infection With the Use of a Left Ventricular Assist Device? The LionHeart Experience in EuropeThe Journal of Heart and Lung Transplantation, 2007
- Arrow CorAide Left Ventricular Assist System: Initial Experience of the Cardio-Thoracic Surgery Center in PaviaThe Annals of Thoracic Surgery, 2007
- Progress in the Development of the DexAide Right Ventricular Assist DeviceAsaio Journal, 2006
- Development of a Small Implantable Right Ventricular Assist DeviceAsaio Journal, 2005
- Initial In Vivo Evaluation of the DexAide Right Ventricular Assist DeviceAsaio Journal, 2005
- Preclinical readiness testing of the arrow international CorAide left ventricular assist systemThe Annals of Thoracic Surgery, 2004
- Chronic Evaluation of the Cleveland Clinic CorAide Left Ventricular Assist System in CalvesArtificial Organs, 2002
- In vivo hemodynamic performance of the Cleveland Clinic CorAide blood pump in calvesThe Annals of Thoracic Surgery, 2001
- The CorAide blood pumpThe Annals of Thoracic Surgery, 2001
- Infection and Thrombosis in Total Artificial Heart Technology: Past and Future Challenges–A Historical ReviewAsaio Journal, 2000