Evaluation of anti-C1q capture assay for detecting circulating immune complexes and comparison with polyethylene glycol-immunoglobulin G, C1q-binding, and Raji cell methods
- 1 August 1987
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 25 (8) , 1567-1569
- https://doi.org/10.1128/jcm.25.8.1567-1569.1987
Abstract
An anti-C1q capture method kit (C1q-immunoglobulin G [IgG]) (Ortho Diagnostics, Inc., Raritan, N.J.) for measuring circulating immune complexes (CIC) was evaluated. The kit showed poor diagnostic sensitivity (P less than 0.005) for identifying CIC in patients with systemic lupus, rheumatoid arthritis, and bacterial endocarditis, as compared with polyethylene glycol-IgG and Raji cell tests (12, 24, and 24 positive, respectively, of 31 patients). Of the patients who were positive with the C1q-IgG test, 25% showed discrepancies when their results were compared with the polyethylene glycol-IgG and C1q-binding test results. Gel filtration chromatography of two of these discrepant sera showed the only peak of C1q-IgG activity to be associated with monomeric IgG (molecular weight, less than 200,000). We concluded that the kit method may be measuring substances other than CIC in some sera, because molecules of C1q attached to IgG should exhibit a molecular weight of greater than 500,000.This publication has 12 references indexed in Scilit:
- Guinea pigs with inherited deficiencies of complement components C2 or C4 have characteristics of immune complex disease.Journal of Clinical Investigation, 1986
- ANTI-IGG COMBINED WITH RATE NEPHELOMETRY FOR MEASURING POLYETHYLENE GLYCOL-PRECIPITATED CIRCULATING IMMUNE-COMPLEXES1985
- Anti‐f(ab′)2 antibodies that interfere with interpretation of the anti‐c3 assay for immune complexes in children with rheumatic diseasesArthritis & Rheumatism, 1984
- The detection of circulating immune complexes containing C1q and IgG using a new rapid serum ELISA test system.1984
- REACTIVITY OF LOW-MOLECULAR WEIGHT MATERIAL IN CELLULAR IMMUNE-COMPLEX ASSAYS1983
- ANTI-C1Q COLUMN - LIGAND SPECIFIC PURIFICATION OF IMMUNE-COMPLEXES FROM HUMAN-SERUM OR PLASMA - ANALYSIS OF THE INTERACTION BETWEEN C1Q AND IMMUNE-COMPLEXES1982
- INTERPRETATION OF THE RAJI CELL ASSAY IN SERA CONTAINING ANTI-NUCLEAR ANTIBODIES AND IMMUNE-COMPLEXES1981
- Raji cell assay for immune complexes. Evidence for detection of Raji-directed immunoglobulin G antibody in sera from patients with systemic lupus erythematosus.Journal of Clinical Investigation, 1980
- Detection of immune complexes in unheated sera by modified 125I-Clq binding test. Effect of heating on the binding of Clq by immune complexes and application of the test to systemic lupus erythematosus.1976
- The Raji cell radioimmune assay for detecting immune complexes in human sera.Journal of Clinical Investigation, 1976