Asymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements
Open Access
- 1 January 1995
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 23 (4) , 491-509
- https://doi.org/10.1080/02786829508965332
Abstract
Several method have been proposed to accelerate the measurements made with differential mobility analyzers (DMA), including the Scanning Electrical Mobility Spectrometer (SEMS) and the Scanning Mobility Particle Sizer (SMPS). Wang and Flagan (1990) developed a data analysis procedure that accounts for the migration of the particles through a time-varying electric field and the delay associated with transport from the analyzer column outlet to the detection point. Experience using a variety of detectors and scan rates has indicated that the instrument response depends on the plumbing configuration if a condensation particle counter (CPC) is used as a detector. When a sharply peaked distribution is analyzed, the apparent breadth of the measured distribution depends on the detector used and on the scan rate. Size distributions measured with an increasing voltage scan exhibit a tail toward large particle sizes, while decreasing voltage scans produce a more pronounced tail on the small particle end of the distribution. The reduction in peak height with increasing scan rate can be attributed to particle retention in the plumbing between the outlet of the DMA analyzer column and the point in the CPC where the particles are detected optically. This paper examines the smearing of the transfer function of the SEMS as a result of flow non-idealities in the system. A model has been developed to predict the distortion of the transfer function in terms of the particle residence time distribution within the instrument. Results of this model are compared with calibration data as a function of the detector employed and the scan rate. We include laboratory observations of the phenomenon and examine the use of data inversion techniques to retrieve the true size distribution.Keywords
This publication has 12 references indexed in Scilit:
- Performance of condensation particle counters with three continuous-flow designsJournal of Aerosol Science, 1992
- Electrical mobility measurements of fine-particle formation during chamber studies of atmospheric photochemical reactionsEnvironmental Science & Technology, 1991
- Scanning Electrical Mobility SpectrometerAerosol Science and Technology, 1990
- EM algorithm reconstruction of particle size distributions from diffusion battery dataJournal of Aerosol Science, 1985
- Linear Inversion Method to Obtain Aerosol Size Distributions from Measurements with a Differential Mobility AnalyzerAerosol Science and Technology, 1983
- Inversion to obtain aerosol size distributions from measurements with a differential mobility analyzerJournal of Aerosol Science, 1982
- Determination of the aerosol size distribution from the mobility distribution of the charged fraction of aerosolsJournal of Aerosol Science, 1978
- Data inversion using nonlinear programming with physical constraints: Aerosol size distribution measurement by impactorsAtmospheric Environment (1967), 1976
- Accurate measurement of aerosol electric mobility momentsJournal of Aerosol Science, 1975
- Comparison of constrained linear inversion and an iterative nonlinear algorithm applied to the indirect estimation of particle size distributionsJournal of Computational Physics, 1975