Microtopography and Soft Tissue Response
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 2 (1) , 51-74
- https://doi.org/10.3109/08941938909016503
Abstract
Implants placed in soft tissue evoke a foreign body reaction. Polymeric implants having smooth surfaces, such as silicone rubber implants, develop a nonadherent fibrogranulous tissue capsule which contracts over time and stiffens. Conventional porous implants, such as those made from textiles, usually have pores larger than 20 μm and they become infiltrated with inflammatory tissue. The in vivo cell reaction to polymeric surfaces having pores smaller than 10 μm has not been investigated systematically. In this study the histocompatibility of materials having mean pore diameters from 0.4 to 10 μm was assessed. A material available with several different defined pore sizes Versapor filter material) was tested in vivo to determine relation between pore size and qualitative tissue response. Silicone-coated samples were also tested to determine the dependence of the observed tissue response on the implant surface chemistry. Results showed nonadherent, contracting capsules around implants having pore diameters smaller than 0.5 μm. Implants with pores ranging from 1.4 to 1.9 μm evoked thin, tightly adherent fibrous capsules without inflammatory cells. Porosities of 3.3 μm and larger became infiltrated with inflammatory tissue. Results indicate that the obsexrved tissue response is predominantly dependent on implant surface topography and that variation in implant material may have little effect. It is concluded that a defined surface topography of 1 to 2 pm appears to allow direct fibroblast attachment to the surface independent of its chemical or electrochemical nature. Attached fibro-blasts then produce a minimal connective tissue response to the implant and prevent or diminish the presence of inflammatory cells at the implant/tissue interface.Keywords
This publication has 11 references indexed in Scilit:
- Inflammatory Response to ImplantsAsaio Journal, 1988
- Normal wound healing compared to healing within porous Dacron implantsJournal of Biomedical Materials Research, 1988
- Cell Adhesion to BiomaterialsAsaio Journal, 1987
- Fibroblasts on micromachined substrata orient hierarchically to grooves of different dimensionsExperimental Cell Research, 1986
- Species-related differences in percutaneous wound healingAnnals of Biomedical Engineering, 1985
- Acrylonitrile: a suspected human carcinogenInternationales Archiv für Arbeitsmedizin, 1984
- STUDY OF ENCAPSULATION OF SILICONE RUBBER IMPLANTS IN ANIMALS A Foreign-Body ReactionPlastic and Reconstructive Surgery, 1978
- LONG-TERM STUDY OF REACTIONS TO VARIOUS SILICONE BREAST IMPLANTS IN RABBITSPlastic and Reconstructive Surgery, 1976
- Host Response to Implanted Dacron GraftsArchives of Surgery, 1975
- Relation of the Equilibrium Contact Angle to Liquid and Solid ConstitutionPublished by American Chemical Society (ACS) ,1964