Recent work has illuminated differences in carotid artery blood flow rate dynamics of older versus young adults. To what degree flow waveform shape, and indeed the use of measured versus assumed flow rates, affects the simulated hemodynamics of older adult carotid bifurcations has not been elucidated. Image-based computational fluid dynamics models of N=9 normal, older adult carotid bifurcations were reconstructed from magnetic resonance angiography. Subject-specific hemodynamics were computed by imposing each individual’s inlet and outlet flow rates measured by cine phase-contrast magnetic resonance imaging or by imposing characteristic young and older adult flow waveform shapes adjusted to cycle-averaged flow rates measured or allometrically scaled to the inlet and outlet areas. Despite appreciable differences in the measured versus assumed flow conditions, the locations and extents of low wall shear stress and elevated relative residence time were broadly consistent; however, the extent of elevated oscillatory shear index was substantially underestimated, more by the use of assumed cycle-averaged flow rates than the assumed flow waveform shape. For studies of individual vessels, use of a characteristic flow waveform shape is likely sufficient, with some benefit offered by scaling to measured cycle-averaged flow rates. For larger-scale studies of many vessels, ranking of cases according to presumed hemodynamic or geometric risk is robust to the assumed flow conditions.Keywords
This publication has 22 references indexed in Scilit:
- Choice of In Vivo Versus Idealized Velocity Boundary Conditions Influences Physiologically Relevant Flow Patterns in a Subject-Specific Simulation of Flow in the Human Carotid BifurcationJournal of Biomechanical Engineering, 2008
- An image-based modeling framework for patient-specific computational hemodynamicsMedical & Biological Engineering & Computing, 2008
- Is flow in the common carotid artery fully developed?Physiological Measurement, 2008
- Geometry of the Carotid Bifurcation Predicts Its Exposure to Disturbed FlowStroke, 2008
- Flow–area relationship in internal carotid and vertebral arteriesPhysiological Measurement, 2008
- Frequency-dependent response of the vascular endothelium to pulsatile shear stressAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- On the Relative Importance of Rheology for Image-Based CFD Models of the Carotid BifurcationJournal of Biomechanical Engineering, 2006
- Inlet Conditions for Image-Based CFD Models of the Carotid Bifurcation: Is it Reasonable to Assume Fully Developed Flow?Journal of Biomechanical Engineering, 2006
- Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteriesPhysiological Measurement, 2005
- Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1985