A proposed method for correcting aperture penetration in high energy slit aperture and pinhole SPECT
- 1 August 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 44 (4) , 1564-1570
- https://doi.org/10.1109/23.632733
Abstract
Aperture penetration in high energy pinhole and slit aperture SPECT results in a decrease of both resolution and contrast. At 511 keV, approximately 50% of projection counts can be attributed to penetration. Correction for this effect by measuring the penetration from a “blocked” slit has been investigated using SPRINT-II. Slit apertures were blocked with small bars of depleted uranium (DU) and projections acquired to serve as an estimate of the penetration background. The block's finite size and DU's limited attenuation of 511 keV photons required the blocked projection data to be corrected by a spatially variant, Monte Carlo based window function. 18F line sources imaged without correction for penetration had an 8.8 mm FWHM and 18 mm FWTM due to large penetration tails. Lines reconstructed with penetration correction achieved 5.0 mm FWHM and 8.6 mm FWTM resolution. An 18F filled ?-Jaszczak phantom (hot lines from 1.5 mm to 4 mm) imaged without correction produced a barely discernible 4 mm line send uniform background. Images produced with correction produced clear images of 3 mm holes with negligible background The findings should be generally applicable to clinical gamma camera systemsKeywords
This publication has 9 references indexed in Scilit:
- Design, construction and performance of one-dimensional lead foil parallel plate and fan-beam collimators for gamma ray imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Space-alternating generalized expectation-maximization algorithmIEEE Transactions on Signal Processing, 1994
- Pinhole collimation for ultra-high-resolution, small-field-of-view SPECTPhysics in Medicine & Biology, 1994
- Small animal imaging with pinhole single-photon emission computed tomographyCancer, 1994
- A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotationPhysics in Medicine & Biology, 1994
- Pinhole emission computed tomography: method and experimental evaluationPhysics in Medicine & Biology, 1990
- SPRINT II: a second generation single photon ring tomographIEEE Transactions on Medical Imaging, 1988
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983